Outlets can be charged continuously (S1) with 3000W and temporarily (S2) for a maximum of 5
minutes with 3300W.
For PRGE5500:
Outlets can be charged continuously (S1) with 2600W and temporarily (S2) for a maximum of 5
minutes with 2800 W or for a maximum of 2 minutes (with a cold engine) with 3100W.
Set the selector (Fig. 13) to the right to activate the 400V 3 ~ socket.
This outlet can be continuously charged (S1) at 3600 W and temporarily for a maximum of 2
minutes at 5500 W (when stopped, the generator being cooled) or for at most 5 minutes at 4800 W
(at operating temperature) .
The generator is suitable for 220-240V~ AC devices.
Do not connect the generator to your home mains as this could damage it to other electrical
appliances in your home.
Important! The generator comes with an overload cut-off.
This disconnects the power outlets in case of overload. If applicable: Reduce the electrical power
you draw from the generator or remove the connected defective devices and then restart sockets by
pressing the safety switch (Fig. 14).
PRGE2800
4.4- Switching off the generator
Before turning off the generator, let it run briefly without any consumers to allow it to cool.