Displays and operating elements

4.1

LED bar

Fig. 5:
Segments of the LED bar
The LED bar provides visual information about the current operating status of the charging
station. It consists of 4 segments ([S1] to [S4]), which can light up or flash, together or
individually, in various colors.
The LED bar is only visible with activated power supply.
Display
Dark
Flashing green
(every 3 seconds)
Flashing blue
(every 3 seconds)
Flashing green
(after plugging in)
Green
Flashing green
(every second)
Flashing green
(every 3 seconds)
Flashing orange
(every 5 seconds)
Blue and orange
Orange
(5 seconds)
Orange (S2)
Flashing red
Blue / red
Red / white
Operating instructions V 1.00 Document: V 1.00 / Document No.: 105728 │ Date 28.05.2018
Displays and operating elements
Description
No power supply or defect, for details see "Diagnosis"
Ready for operation
or with authorization option: Authorization done correctly
The charging station is waiting for authorization to enable a charging
process.
Locking of the charging cable to the charging socket
The plugged-in charging cable is locked and charging can be started by
the vehicle.
Execution of a charging process (applies to "EN 61851 Mode 3"
charging process)
Charging finished and charging socket unlocked. The charging cable
can be unplugged.
Temperature exceeded, the charging process is temporarily in-
terrupted and resumed after cooling down.
The charging station is in startup.
Self-test during startup
The charging station is in commissioning mode.
Error, for details see "Diagnosis"
Error display via color code, for details on possible causes of er- ror and
troubleshooting see "FAQs" on the ABB website