To Shut Down Unit; Ignition Control Diagnostic Codes; Wiring And Ladder Diagram - Dometic hydro flame AFM Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.
Set thermostat above room temperature to begin blower
operation. A slight delay will occur before the blower comes on.
Allow blower to run for 1 minute for combustion chamber purge
cycle. If blower does not come on or stops before ignition cycle,
shut down unit and contact your dealer or a local recreational
vehicle service agency.
3.
After 1 minute, the blower may not be running at this time, move
thermostat lever below room temperature. Wait approximately 2
minutes for blower to go off.
4.
Open manual shut-off valve (if so equipped) or the valve at the
outside LP tank. Correct operation characteristics depend on the
valve being positioned fully open. Never attempt to operate with a
valve partially closed. Turn shut-off switch to "ON" position.
5.
Set thermostat lever to desired setting. If set above room
temperature, blower will come on.
6.
Allow 30 seconds for main burner to light after blower comes on.
This furnace is equipped with an ignition device which
automatically lights the burner. DO NOT try to light the burner by
hand.
7.
If burner does not light, repeat Steps 1 through 5.
8.
If after three (3) attempts with no ignition, shut down the unit and
contact your dealer or a local recreational vehicle service agency.
Do not continue to cycle furnace through thermostat in an attempt
to get ignition.

WIRING AND LADDER DIAGRAM

TO SHUT DOWN UNIT

Set the thermostat to lowest setting, move lever to "OFF" position.
1.
Turn manual shut off valve (if so equipped) to the "OFF" position.
2.
Do not force.

IGNITION CONTROL DIAGNOSTIC CODES

The following charts give the diagnostic codes given by the ignition
control when faults are present.
A soft lockout is a condition that is timed and will make additional
attempts to correct the problem. A hard lookout requires resetting
of the thermostat or turning the power switch off, then back on.
STANDARD 3 TRIES FOR IGNITION CONTROLS
FAULT
Internal Circuit Board
Failure
Limit Switch/Airflow
Problems
Flame Sense Fault
Ignition Lockout Fault
8
DIAGNOSTIC CHART
LED INDICATION
Steady On, No Flashing
1-Flash With 3-Second
Pause
2-Flashes With 3-Second
Pause
3-Flashes With 3-Second
Pause
LOCKOUT
Hard
Soft
Hard
Soft (1hr.
retry)