Properly seal vent assembly to prevent carbon monoxide from entering
coach.
DO NOT draw combustion air from living area.
DO NOT vent exhaust air into the living area or an enclosed porch.
WARNING
Furnace must be installed and vented according to these
instructions.
Improper
installation,
adjustment,
maintenance can cause injury or property damage.
Improper installation location may cause furnace to produce negative
pressure, affecting combustion air or venting of other appliances.
WARNING
CARBON MONOXIDE POISONING
Properly seal door to prevent carbon monoxide from entering
coach.
Properly adjust draft cap to prevent carbon monoxide from entering
coach.
MODEL NOMENCLATURE
AF
M
D
25
Dometic
Cabinet
Voltage
Input
Furnace
Size
Btu/hr
AF
M=medium
D=12
16K
VDC
20K
25K
30K
35K
Contents
MODEL NOMENCLATURE ....................................................... 2
MODEL SPECIFICATIONS ....................................................... 2
DIMENSIONS ................................................................................... 2
INSTALLATION AND SAFETY CODESError! Bookmark not defined.
INSTALLATION CODES ................... Error! Bookmark not defined.
REQUIRED DUCTING ...................................................................... 3
AIR FLOW CHECK ........................................................................... 4
SIDEWALL CUTOUT ....................................................................... 4
GAS CONNECTION .................................................................. 6
TO SHUT DOWN UNIT ..................................................................... 8
alteration,
service
or
1
1
1
A
Gas
Gas
Valve
Model
Type
Location
Rev
1=LP
1=door
1=Single
A
2=LD (small
vent)
3=door w/
rear gas
fitting
4=door
w/pigtail
5=door w/
pigtail & rear
gas fitting
MODEL SPECIFICATIONS
Models
AFMD16
Type of
LP
Gas
Propane
BTU Input
16,000
BTU
12,160
Output
.20" WC
Duct
Static
Pressure
Amperage
4.2*
(AMPS)
Watts
50
Power
12
Supply
(Volt DC)
2
Return Air
80 in
2
Minimum
65 in
Return Air
WATER
(WC =
COLUMN)
*
15 AMP DECATATED CIRCUIT FOR FURNACE
DIMENSIONS
Approx.
Width
Casing
16-1/2"
STD Door
19-1/4"
FLUSH
19-3/8"
DOOR
Vent LD
5-1/2"
INSTALLATION AND SAFETY CODES
USA and Canada - follow all applicable state and local codes in
the absence of local codes or regulations, refer to current
standards of:
ANSI/NFPA 1192 Recreational Vehicles Code and ANSI/RVIA LV
Low Voltage Systems in Conversion and Recreational Vehicles
CSA Z240.4, Gas-Equipped Recreational Vehicles and Mobile
Housing
National Fuel Gas Code ANSI Z223.1 and/or CAN/CGA B149
This furnace must be installed in accordance with the
manufacturer's instructions and the manufactured Home
Construction and Safety Standard, Title 24 CFR, part 3280, or
when such standard is not applicable, the Standard for
Manufactured Home Installations. (Manufactured Home Sites,
Communities and Set-Ups), ANSI A255.1 and/or CAN/CSA-Z240
MH Series M92 Canadian Standard for Mobile Homes."
ANSI A 255.1 and/or CAN/CSA-Z240.6.2 MH Series, Mobile
4
Homes
Ground National Electrical Code ANSI/NFPA 70 and/or CSA
C22.1, Part 1
Park Trailers ANSI 1195
GENERAL FURNACE INSTALLATIONS
All models can be installed in either a horizontal or vertical
mounting position horizontal installed units have the gas line
positioned on top or rear, vertical installed units must have the
vent located at the floor and gas line at right side and rear.
Always install furnace through an exterior wall.
DO NOT install furnace near tilt-out rooms, slide-outs, doors or
other projection that could obstruct furnace exhaust.
Locate furnace near midpoint of coach for single furnace
applications.
Installation must provide accessibility if any repairs are necessary
to the furnace. Failure to meet this requirement will create
additional labor costs that will be the responsibility of the installer.
2
AFMD20
AFMD25
AFMD30
LP
LP
LP
Propane
Propane
Propane
20,000
25,000
30,000
15,200
19,000
22,800
.10" WC
.10" WC
.10" WC
4.2*
7.5*
7.5*
50
90
90
12
12
12
2
2
2
80 in
80 in
80 in
2
2
2
65 in
65 in
65 in
Height
Depth
7"
20"
3/4"
9-3/4"
7/32"
10-1/4"
5-1/2"
1-1/16"
AFMD35
LP
Propane
34,000
25,840
.10" WC
11.1*
132
12
2
80 in
2
65 in
Weight
Furnace
26lbs.
Boxed
29 lbs.