HOW THE ELECTRONIC UNIT OPERATES
• The YELLOW LED 11 (fig. H) (ALIM) is lit
when the power supply is operating.
• The GREEN LED 9 (fig. H) (EV) is lit when the
detector senses hands in the detection zone
and the solenoid valve opens the water flow.
When the hands are removed, the flow stops
and the GREEN LED goes out.
• The RED LED 10 (fig. H) (SECUR) is lit and the
flow of water stops if the detector senses
hands (or any other object) continuously for 45
seconds; the anti-blocking safety is activated.
Once the hands or object are/is removed the
system is reset and a new cycle can commence.
For the electronic unit to operate correctly the
ambient temperature should be between 5°C
and 40°C.
Fig. H: 9 = Green 10 = Red 11 = Yellow
ADJUSTMENT
• The detection distance can be adjusted from
8 to 25cm using the potentiometer "GAIN" 3
(fig. F) located on the electronic unit.
• The duty flush is programmed to flush
automatically for 45 seconds every 24 hours
after the last use. This can be cancelled or
programmed to flush 12 hours after the last
use 8 (fig. F) by placing the connecting pins in
line with the desired programme.
TEMPERATURE LIMITATION (MIXERS)
For the UK and Ireland we recommend installing
an appropriate, approved thermostatic mixing
valve (TMV) to provide safe, anti-scald hot water.
Where thermostatic mixing valves are
installed the temperature limiter MUST BE
REMOVED from all point-of-use mixers.
Recommended maximum temperature
settings are: bidets 38°C, washbasins and
showers 41°C. For all other countries please refer
to the relevant hot water safety guidelines.
Side temperature selector (fig. K)
The product is delivered with the maximum
temperature limiter engaged. To override it:
• Isolate the water supply.
• Loosen the grub screw at the back of the mixer
body using a 4mm Allen key and remove the
temperature selector.
• Prise upwards with a flat-headed screwdriver
12 to remove the coloured limiter 13.
• Re-assemble and commission in line with the
TMV manufacturer's instructions.
• When used with a TMV, always carry out a cold
water failsafe check.
Central temperature selector (fig. L)
The temperature limiter is fixed in position B at
the factory. It is possible to change it to position
A to limit the temperature, or remove it to
override the limiter.
• Isolate the water supply.
• Loosen the locking screw using a 2.5mm Allen
key and remove the temperature selector lever
14.
• Carefully pull-out the detector 15 a few
centimetres.
• Loosen the limiter 16 using a 2mm Allen key
and change the setting or remove the limiter as
required.
• Re-assemble and commission in line with the
TMV manufacturer's instructions.
• When used with a TMV, always carry out a cold
water failsafe check.
ADJUSTING THE FLOW RATE
The flow rate is pre-set at the factory at 3 lpm (at
3 bar).
• The flow rate can be adjusted directly on the
flow straightener using a 2.5 mm Allen key:
- Notch n°1 = 3 lpm (at 3 bar)
- Notch n°2 = 4 lpm (at 3 bar)
- Notch n°3 = 5 lpm (at 3 bar)
GB