REMEMBER
• Sizing the pipes correctly will avoid
problems of flow rate, pressure loss and water
hammer (see calculation table in our brochure
and online at www.delabie.com).
• Protect the installation with filters, water-
hammer absorbers and pressure reducers to
reduce the frequency of maintenance
(recommended pressure: 1 to 5 bar).
• Install stopcocks close to the mixer/tap to
facilitate maintenance.
• The pipework, stopcocks, bib taps and all
sanitary fittings should be checked at least
once a year, and more frequently if
necessary.
MAINTENANCE AND CLEANING
• Cleaning chrome:
Do not use abrasive, chlorine or acid-based
cleaning products. Clean with soapy water
using a cloth or a sponge.
• Frost protection:
Drain the pipes and operate the mixer/tap
several times to drain any remaining water.
MAINTENANCE
In sleep mode, the YELLOW LED 11 (fig. H) is
lit. If it goes out, check the power supply at terminal
7 (fig. F) and replace the fuse if necessary. If the
problem persists, replace the electronic unit.
If the mixer/tap flows continuously:
Shut-off the 220-240V~ electricity supply. If the
water stops flowing, replace the electronic unit, if
not, check the mounting direction of the solenoid
valve (fig. G), then clean/rinse the outlet, lifting the
valve with a small screwdriver. Replace and do not
forget to replace the filter.
For Delabie UK Ltd market only: Tel: 01491 824449 e.mail: technical@delabie.co.uk
For all other markets : Tel: +33 (0)3 22 60 22 74 e.mail: sav@delabie.fr
The most recent version of this installation guide is available on: www.delabie.com
After Sales Care and Technical Support:
If the water does not flow when hands are
placed in front of the detector:
• RED LED 10 (fig. H) is lit: the device is in security
mode. An object in front of the detection cell has
triggered the anti-blocking security after the
comfort shut-off delay. Remove the object.
• GREEN LED 9 (fig. H) has gone out: the
detection cell is dirty or has a bad connection
on the BMR terminal.
- Check and clean the detection cell.
- Check the direction and the quality of the
cables.
- Check that the wires are not touching.
- Check that the detector cable has not been
lengthened or shortened (standard length: 70 cm).
• GREEN LED 9 (fig. H) is lit and the water is
not flowing: the solenoid valve is not
opening.
- Check that the filter is clean.
- Check that the voltage to the solenoid valve
is 12V ac. If it is, replace the solenoid valve, if
not, check that the supply cable is properly
connected to the terminal, or that it has not
be cut.
Beware: do not grease the inside of the
mechanism.
Mixer: regularly check (as often as necessary) the
temperature selector and the mixer's two internal
seats on which the mixing key turns. Replace as
necessary.
NB: The non-return valves should be checked at
least once a year.
Product conforms to current European
Directives.