Display; Ventilation; Starting-Up And Appliance Management; Before The First Use - Novy Flex Zone 1706 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Display

Display
0
1...9
U
A
E
H
P
U
II

Ventilation

The cooling system is fully automatic. The cooling fan starts with a low speed when the
calories brought out by the electronic system reach a certain level. The ventilation starts his
high speed when the hob is intensively used. The cooling fan reduces his speed and stops
automatically when the electronic circuit is cooled enough.

STARTING-UP AND APPLIANCE MANAGEMENT

Before the first use

Clean your hob with a damp cloth, and then dry the surface thoroughly. Do not use detergent
which risks causing blue-tinted colour on the glass surface.

Induction principle

An induction coil is located under each heating zone. When it is engaged, it produces a
variable electromagnetic field which produces inductive currents in the ferromagnetic bottom
plate of the pan. The result is a heating-up of the pan located on the heating zone.
Of course the pan has to be adapted:
 All ferromagnetics pans are recommended (please verify it thanks a little magnet): cast
iron and steel pans, enamelled pans, stainless-steel pans with ferromagnetic
bottoms...
Are excluded : cupper, pure stainless-steel, aluminium, glass, wood, ceramic,
stoneware,...
The induction heating zone adapts automatically the size of the pan. With a too small
diameter the pans doesn't work. This diameter is varying in function of the heating zone
diameter.If the pan is not adapted to the induction hob the display will show [ U ].

Starting-up

 Start-up/ switch off the hob
Action
To start:
To stop:
Designation
Zero
Power level
Pan Detection
Heat accelerator
Error message
Residual heat
Booster
Keep Warm
Pause
Control panel
Touch the key [ 0/I ]
Touch the key [ 0/I ]
Function
The heating zone is activated
Selection of the cooking level
No pan or inadequate pan
Automatic cooking
Electronic failure
The heating zone is hot
The boosted power is activated
Maintain automatically at 70°C.
The pause is activated