Operating conditions
US
Cold water temperature
Hot water temperature
Recommended water temperature
Thermal disinfection (3 10 Min.)
Permissible flow pressure
Maximum flow pressure
Recommended flow pressure
The customer has to provide a pressure
reducer in the main line downstream of the
water meter to comply with the noise levels
according to the noise class at a resting
pressure above 5 bar / 73psi.
If combined with continuousflow heaters, the
minimum flow volume of the safety shutoff
has to be considered.
Observe the manufacturer's instructions for
the continuousflow heater.
Electrotechnical Data
Rated voltage
Input frequency
Output voltage
Rated power
Degree of protection
Sensor frequency
i
NOTICE!
Devices with the same frequency can interfere
with each other's functions.
Permissible Ambient Temperature 41 - 95 °F
Storage
Store somewhere dust-free and dry!
34
41 - 77 °F
131 - 149 °F
140 °F
≤ 158 °F
15 73 psi
73 psi
45 psi
100 - 240 V AC
50 - 60 Hz
12 V DC
5 W
IP X4
5,785 - 5,815 MHz
41 - 95 °F
Driftsvillkor
SE
Kallvattentemperatur
Varmvattentemperatur
Rekommenderad
varmvattentemperatur
Termisk desinfektion (3 10 Min.)
Tillåtet flödestryck
Rekommenderat flödestryck
En trycksänkare ska monterats in i huvudled-
ningen efter vattenmätaren för överensstäm-
melse med bullervärdena vid ett vilotryck över
5 bar.
Vid en kombination med genomströmnings-
beredare ska den minsta flödesmängden för
säkerhetsavstängningen beaktas.
Följ anvisningarna från tillverkaren av genom-
strömningsberedaren.
Elektrotekniska data
Märkspänning
Ingångsfrekvens
Utgångsspänning
Märkeffekt
Kapslingsklass
Sensorfrekvens
i
MEDDELANDE!
Utrustningar med samma frekvens kan störa
varandras funktioner ömsesidigt.
Tillåten omgivningstemperatur
Förvaring
Förvaras dammfritt och torrt.
5 - 25 °C
55 - 65 °C
60 °C
≤ 70 °C
1 5 bar
3 bar
100 - 240 V AC
50 - 60 Hz
12 V DC
5 W
IP X4
5.785 5.815 MHz
5 - 35°C
5 - 35°C