Automatic Cellar Dehumidification Aero_aH100
2.
Insert the supplied internal climate sensor
[5] correctly (
sockets.
3.
Fit cover [4].
7.6. Start up
1.
Switch the mains fuse on.
2.
Run function test.
3.
Save reference humidity by pushing button
1 [15].
4.
Fit designer cover [3].
Saving of the reference values is
shown by LED 1 blinking.
8. Maintenance
The unit is maintenance-free.
9. Cleaning
Danger to life from electric
shock.
DANGER
Switch the mains fuse off
arrow X) in the connector
.
Risk of damage to unit if incorrect
NOTICE
cleaning agent is used.
Only use water to clean cover [4]
and designer cover [3]. Do not use
aggressive cleaning agents.
1.
Only use a dry cloth to clean the internal
parts of the fan.
2.
If the designer cover [3] is very dirty,
remove it carefully from the fan and clean
with water.
3.
Fit designer cover [3].
10. Fault rectification
Call on the services of a trained electrician
any time there is a fault.
Repairs should only be carried out by a
trained electrician.
Danger to life from electric
shock.
DANGER
Switch off mains fuse before
working on electrical
connection.
Both LEDs off
No mains voltage.
Check whether the mains fuse
has failed. Switch on if
necessary.
Both LEDs
Internal climate sensor error.
blink three
The internal climate sensor has
times
not been detected. Check for
firm seating and correct
mounting orientation.
Both LEDs
External climate sensor error.
blink five
The connection to the external
times
climate sensor is interrupted.
Check the sensor connection
cable and plug contact.
Impeller blocked.
Fan does
Should only be carried out by a
not switch on.
trained electrician: Remove
cover [4]. Unlock internal grille
1019-1-0002 Handbuch Version: DE_170830_TOLI_aeroaH100|
21