Automatic Cellar Dehumidification Aero_aH100
Feed power cable into the
connection area such that the cable
grommet fits around the cable
sheathing completely and does not
penetrate too far into the connecting
area
.
7.
Insert housing [1] into wall breakthrough/
wall sleeve and secure with two screws.
Do not insert the housing such that it is
twisted or crushed. Make sure you use
mounting material which is sized for the
purpose.
8.
Lay sensor connection cable [12] in the
provided recesses (I, II) and plug it [A]
into the electronic circuit board [7].
7.4. Electrical connection
Danger to life from electric
shock.
DANGER
Switch the mains fuse off.
Risk of damage to unit in the
NOTICE
event of short-circuits.
Insulate PE conductor and
individual cable cores that are
not required.
1.
Only lay single cable cores in the unit. To do
this, remove power cable sheathing over a
length of 70mm. Strip single cable cores to
9 to 10 mm.
2.
Electrically connect power cable to spring
clip [13] according to connection wiring
diagram [13], also see wiring diagram in
Chapter 13.
3.
Check position of cable grommet [9]. It
must be well sealed.
7.5. Final assembly
Danger of short-circuits and
NOTICE
damage to the unit. Humidity
will penetrate if electronics
cover is not fitted correctly.
Press electronics cover firmly
onto housing such that it is
sealed and flush all the way
around. When doing so, do not
press setting buttons [15] and
[16].
Before fitting the electronics cover,
check the location of the external
climate sensor's connection cable to
make sure that the mounting of the
internal
climate sensor
blocked.
1.
Insert electronics cover [6] into housing
recesses I, II and III, until the 3 locking tabs
snap into place. Press the electronics
cover firmly on to the housing at the
points indicated by the arrows