QCC-LCS TS - REV002A
INSTALLATION
6
• Always disconnect the supply voltage during installation and maintenance operations.
• Prepare a drilling for a standard 503 electrical box (not supplied), on the wall or installation panel.
• Install the standard 503 electrical box.
• Fix the installation frame (1) to the 503 electrical box.
• Insert the cables coming out from the 503 box into the two casing openings (3).
• Connect the power supply and the DMX512 bus to the terminals on the back of the display (2) - see connection diagram.
• Fit the casing (3) on the back of the display (2).
• Place the display (2) on the installation frame (1) and fix with four screws included in the package.
The upper screw on the right side (4) and the lower screw on the left side (4) have a positioning function and must be
pressed in place. The two remaining screws (5) must be screwed on without excessive tightening.
• Fit the outer frame (6) to the installed display (2).
WIRING DIAGRAM
Wiring, terminals and cables
Considering the high currents involved, a few
precautions on wiring are in order:
• Cable size should range from 0.5 mm
• Peel off cables by 8 mm to add the terminal.
• After having completed the installation or
maintenance operations, make sure the work has
been executed properly.
WARNING: MAKE SURE THE POLARITY IS RIGHT.
F
Connection diagram with several devices
on page 57.
QUICK SPA
2
5
SCREWS
4
DISPLAY
EXTERNAL
FRAME
to 1.5 mm
2
2
INSTALLATION / WIRING DIAGRAM
3
4
SCREWS
CARTER
5
POWER SUPPLY
VIN: 10÷30VDC
17
1
INSTALLATION
FRAME
BUS
DMX512
B A
BACK DISPLAY
EN
503
ELECTRICAL
BOX
INSTALLATION
PANEL