3. Installation of an interchangeable scale
Conversion Table % to litres
1. For tanks with a rectangular cross section
6
- To adjust the gauge to the size of the tank, proceed as follows
(see diagramm below):
- Pull out a length of float line corresponding to the height of the
tank plus the projection of the manhole or flange nozzle, if
applicable. Measure the lenght from the top to the bottrom of
the G2 thread.
- Turn the adjustment screw to the right to set the pointer to zero.
The UNIMES gauge ist now correctly set for the size of the
tank.
Remove the protective glass (using a screwdriver). Turn the poin-
ter from right to left up to the centre of the scale.
Hold the pointer in this position and push the cutout in the inter-
changeable scale over the pointer. Release the pointer, which
will then jump bach to the 100 % position.
Install the protective glass by simply pressing it bach into position.
Using this table, the percentage readout of the gauge can be
converted into a fuel oil volume in litres.
The percentage values indicated correspond to percentages of
the total volume. The volume of oil in the tank can be calculated
by multiplying the percentage indicated by the total volume of the
tank.
23
Example:
100
x 5200 l = 1196 l
Unimes