With or without shock function: 1/4", 3/8", 3/8" shock
Hose mounting:
To piston rod end
To cylinder end
To tractor
Content:
•
Diode*
•
Fuse holder
•
Hirschman socket
•
4 m twin conductor
•
Terminal; female + male
•
Lever with switch (not standard)
*NOTE! The diode must be fi tted between
plus and minus inside the Hirschman
socket. Otherwise there is a risk of the
switch in the lever breaking due to sparking.
Electric valve with shock function
When in use ploughs equipped with this
type of electric valve should not be operated
with the pistons fully retracted. They should
be extended approx. 50 mm. Otherwise the
shock function is triggered.
The valve is adjustable with respect to
opening pressure.
English
ELECTRIC VALVE
Hirschman socket
Magnet
To piston rod end
To cylinder end
Valve block
24