3.3.2 « AUTOMATIC COUPLING » devices
Automatic version (IT3600A) detects input isolation transformer network and automatically switches to the
corresponding voltage configuration.
Beforehand, only outputs must be manually configured using cables provided in the accessory bag.
* Output Coupling must be done in accordance with the on board need. An error in the choice could cause the
destruction of the on-board pieces of equipment.
115VAC output voltage configuration :
230VAC output voltage configuration :
3.3.3 Isolation transformer Leds indicators
These Leds are visible on the casing front panel
White Led
Green Led 115VAC
Green Led 230VAC
Red Led
Input voltage
0 – 70 V
70 – 135 V
135 – 185 V
185 – 265 V
presence of mains network
input coupling to 115VAC network
input coupling to 230VAC network
equipment overheating (by internal transformer thermostat)
White Led
« Network »
ON
ON
ON
ON
CAUTION
Green Led
Green Led
115VAC
230VAC
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
coupling
System condition
xx
115VAC input configuration
xx
230VAC output configuration
Output
24