Impossible calibration
Deviation between pool ph
and set point
No injection
Chemical leaks from the
dosing head
No rotation
Please rinse the pump with clear water before any intervention or before sending to after sales service
7.0 GUARANTEE
The doseco are guaranteed against all material and/or manufacturing defects for 1 year as from the date of
delivery to the user except peristaltic hose and probe (weart and tear parts)
These guarantees are granted subject to strict compliance with the assembly and/or maintenance instructions.
No guarantee can be granted if the goods have not been paid for in full. No repairs or replacements carried out
under guarantee can result in any prolongation of the said period of guarantee.
The purchase invoice must be forwarded with any claims under guarantee. Under the terms of this guarantee, the
sole obligation placed on Aqualux is replacement or repair free of charge, as Aqualux sees fit, of the product or
element found to be defective by the competent Aqualux department. All other costs must be met by the
purchaser.
To benefit from this guarantee, all the products concerned must be forwarded beforehand to the AQUALUX
after-sales department, whose approval is essential for all replacements or repairs.
The guarantee does not cover any visible defects, or any defects or damage caused by normal wear and tear,
defects resulting from faulty assembly and/or misuse, or any modifications made to the product without the prior
written approval of AQUALUX.
Legal guarantee:
Provided that the purchaser is able to provide proof of a hidden defect, the seller is required by law to make
good all the consequences thereof (article 1641 et seq. of the French civil code).
If the purchaser brings a claim before the courts, he must do so within two years as from the date at which the
defect comes to light (article 1648 of the French civil code).
Note on environmental protection
After the implementation of the European Directive 2002/96/EU in the national legal system, the
following applies:
Electrical and electronic devices may not be disposed of with domestic waste. Consumers are obliged
by law to return electrical and electronic devices at the end of their service lives to the public
collecting points set up for this purpose. By recycling, reusing the material or other forms of utilising
old devices, you are making an important contribution to protecting our environment.
NOT103453 - ind B - 0212
Electronic regulator out of order
Probe out of order
Worn buffer solution
Wrong positionning of the probe
Wrong calibration
Low Product level
Air in pipe
Check valves plugged or out of order
Time worn peristaltic hose
Time worn roller
Nuts overtight, time worn peristaltic
hose
Micro motor out of order
Electronic regulator out of order
13 /18
Contact your dealer
Replace the probe (wear and tear part)
Replace the buffer solution
Check hydraulic installation
Re calibrate the probe and the set point
Fill the tank
Inititiate the pump
Rinse with water or replace
Change the hose
Change the roller and roller holder
Check that the hose clamps are correctly
fitted and tightened, Change the hose,
nuts, check valves
Contact your dealer
Contact your dealer