MOUNTING
Orientation
This fixture may be mounted in any position, provided there is adequate room for ventilation
It is important never to obstruct the fan or vents pathway.
When selecting installation location, take into consideration lamp replacement access and routine maintenance.
Safety cables must always be used.
Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or
restricted ventilation.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer
or his service agent or a similar qualified person in order to avoid a hazard.
Make sure the installation position is stable before you fix the light. When the light is reverse hanging, make sure the
light will not fall from the truss, use the safety cable go through the truss and bracket of the light as a supporting, to
avoid the light to fall down. There is no entrance to the work area during mounting. Periodically check if the safety
cable has fretted away or clamp is loosened. We will not take any responsibility for damages caused by a badly
installed unit.
Power Supply and Signal Cable Connection
1. Mains Power connection
The exclusive plug should be used between the connection of unit and power. Please ensure that the rated voltage
and frequency are accordance with the power supply. The required input voltage and frequency are: 100-240Vac –
50-60Hz
We suggest that every light has an independent switch so that you can turn on or turn off the light randomly.
Note: the ground wire (yellow/green double-color wire) must be safely connected, the electrical installation must be
in accordance with the related standards
CAUTION: When installing the device, make sure there is no highly inflammable material within a distance of
min.5m!
2. Connection of Signal Cable
You can use the 3-pin XLR cable to connect the output socket of the master and the input socket of the slave light.
Connect the DIGITAL OUT socket of the master and the IN socket of the slave light, then, connect the OUT socket to
the IN socket of the next light. Ordinal to connect all the lights as below:
1
2
3
I N
I N
I N
O U T
O U T
O U T
The connection between the output of master and input of product, it's available to use the 3 pins XLR cable which
provided by the manufacturer. Signal cable from the DMX output of the controller to the input of the first master light,
and connect to the DMX input of second slave light from the DMX output of the first master light, analogously, till
connected all the slave lights, and insert the last connector to the output of the final light. (Notice: the diameter of
core of every cable should be 0.5mm at least, double core shelter cable should be used).The signal connecting must
use the attached 3 pins XLR cable. Notice, all the internal lead wire of the 3 pins XLR cable should not touch to each
other or connect to the connector.
A DMX signal terminator is recommended on the last unit of the chain. DMX terminator is a XLR connector with a
120Ω resistor between the pin 2 and pin 3 of the XLR connector