Connecting The Outputs - MC Crypt 59 08 00 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Start-Up

Connecting the Outputs

The maximum load capacity is 5A (resistive load) per output. The total load capacity for the
device is no more than 16A. Never exceed the total load capacity or the load capacity of the
separate outputs.
Insert the mains plug of the devices to be controlled into the 4 output sockets.
The fuses for the outputs are numbered to clearly identify the sockets.
Mains Connection
The DMX Power Pack has to be connected to a mains socket with protective conductor contact.
Connect the device only when the electric installation has an integrated ground fault circuit
breaker.
The mains outlet to which the DMX Power Pack is connected must be easily accessible so that
the device can be quickly separated from the mains voltage in case of an error.
If the device is connected directly to the mains grid, there must be an integrated all-pole
separator (switch) with a contact opening of min. 3 mm.
Do not let the mains cable come into contact with other cables.
Be careful when handling the mains cables and mains connection. Mains voltage can lead to
a fatal electric shock.
Make sure that no cable lies around openly. Install cables professionally to prevent accidents.
Put the plug of the power line into a grounded wall socket.