Connection of an Analogue Controller

The ANALOG socket is only intended for connecting analogue light control devices with a
control signal of 0-10V direct current.
The connection supplies electric power to the analogue controller. Never connect devices to
it that use another operating voltage than 15V= DC or a higher current input than 500mA.
Connect the ANALOG IN port with the output of your analogue light control device.
Connect the ANALOG THROUGH port with the input of another device that is to be controlled by the analogue
controller.
The ANALOG port has the following pin assignment. Before connecting the device, ensure that your light control
device is suitable for this connection.
Pin1
Channel1
Pin2
Ground
Pin3
Channel4
24
Pin4
Channel2
Pin5
Channel3
Pin6
free
Pin7
free
Pin8
Output: 15V=/ 500mA