Connection of a DMX Controller

The DMX input is only intended for connecting a DMX controller with DMX-512 protocol.
Connect the DMX IN port with the output of the DMX controller.
Use a screened XLR cable. The controller must have one or four free control channels.
Connect DMX OUT with the DMX input of the subsequent device. If the Power Pack is the last or only device in
the DMX chain, insert a plug with a 120 Ohm/0.25 W terminating resistor here (between pin2 and pin3).
Pin assignment of the DMX connection: Pin1 = ground / Pin2 = (-) / Pin3 = (+)