Remote control storing
As START button:
Ÿ Close the gate. Press once the button PROGR; led DL6 starts flashing.
Ÿ Press the remote control button you want to store; led DL6 switched off as
confirmation that code has been stored.
You can store up to max. 32 different codes for the Start.
As Pedestrian button:
Ÿ Close the gate. Press twice the button PROGR; led DL6 starts flashing.
Ÿ Press the remote control button you want to store; led DL6 switched off as
confirmation that code has been stored.
You can store up to max. 32 different codes for the Pedestrian.
Remote control cancellation.
Cancellation of a single code stored into START or PEDESTRIAN:
Ÿ Press at the same time both buttons PROGR and PAUSA; led DL6 starts flashing
quickly.
Ÿ Within 10 sec. press remote control button you want to cancel; led DL6 switches
off to confirm the cancellation.
Cancellation of all codes stored into the control panel:
Press at the same time both buttons PROGR and PAUSA for about 10 seconds.
Led DL6 starts flashing quickly and after 10 seconds will switch off confirming the
cancellation has been done.
Preliminary checks before setting the control panel.
Ÿ Power the control panel and verify that LED Stop, Foto, Foto AP and Costa are
on; if this doesn't correspond, re-check the wirings and or safety devices state.
Any NC contact not used, has to be wired/closed.
Ÿ Verify that all safety devices installed in the gate are working properly in order to
reduce any possible accident.
Ÿ Verify the correct wirings, keeping in mind that 1
gate, otherwise, just swap the wires 17-18 for M1 and/or 19-20 for M2.
Automatic setting of the stroke with leaves delay and slowing down spaces fix.
Following instruction are for a 2 leaves swing gate; in case of 1 single swing leaf
(dip 1 SW1 ON) the instruction regards only the motor M1.
Ÿ Place the leaves half way opening; keep pressed the button PROGR. until both
operators will start closing (approx. 10 seconds).
Ÿ The control panel closes the leaves until they touch the mechanical stoppers.
Ÿ M1 starts opening and after 3 seconds M2 starts opening too.
Ÿ Both operators will stop automatically at the mechanical stoppers in opening.
Ÿ Then, the control panel will close the leaves finishing with a slowing down before
touching the mechanical stoppers in closing.
Ÿ The control panel automatically goes out from the setting and it is ready to work.
In the automatic setting, the delay between the 2 leaves is 3 seconds both in
opening and closing and the slowing down is approx. 4 seconds before reaching the
mechanical stoppers.
WARNING: In case of re-adjustment of the trimmer RALL. or VELOC. it is
ABSOLUTELY necessary to repeat the setting.
(recommended to be done with the antenna disconnected).
st
START impulse has to open the

Publicité

loading