Télécharger Imprimer la page

vds ELB24-M2 Manuel D'instructions page 10

Publicité

Les langues disponibles

Les langues disponibles

LED description.
PED
It shows the output Pedestrian (normally switched off).
START
It shows the output Start (normally switched off).
STOP
It shows the output Stop (normally switched on).
It shows the output Foto
FOTO
(normally switched on, and if the photocells is engaged it switched off).
It shows the output Foto AP
FOTO AP
(normally switched on, and if the photocells is engaged it switched off).
It shows the output safety edge
COSTA
(normally switched on,B3 and if the safety edge is engaged it switched off).
DL6
It shows the state of the setting.
DL7
Shows the status flash
Close the gate and check that LED stop, foto, foto ap and costa are switched on; otherwise
re-check the wirings.
Trimmer description.
AMP
Anti-crashing (obstacle detention) adjustment, when the gate is moving.
RALL.
All adjusted anticlockwise (-) you get an high sensitivity so in case a small
obstacle is on the way, the gate stops. All adjusted clockwise (+) you get a low
sensitivity so in case a small obstacle is on the way, the gate doesn't stop.
VELOC.
This parameter measures the safety of the gate and it has to be adjusted
according to the local norms.
Dip Switches SW1 & SW2 features.
ON
1
Working with 1 motor. Use input M1..
2
Feature "close immediately" enable. When the gate is opening,
as soon as the photocells are disengaged, the gate closes
after 5 seconds.
SW1
3
First push in an opposite way to release the electro-lock
(for gates with electro-lock only).
4
Extra push while starting disable.
1
Residential feature enable (while opening the control panel
does not accept any other Start impulse). When gate has
opened, a Start impulse closes the gate without considering
the automatic shutting set on it. Residential feature disable.
Step by step feature enable also during opening.
2
Enable the indicator of gate movement/position on inputs
SW2
10-11 (LOCK).
3
Enable use of resistive safety edge of 8K2.
4
Release
Fuses description.
F1 - 20A 250V Output battery protection fuse (27-28). - F2 - 20A 250V Transformer output 24Vac protection fuse.
FR1 - 0,65A 250V
Main power supply 230Vac self-repairing protection fuse (non replaceable).
FR2 - 1,6A 250V Self-repairing protection fuse for photocells, electro-lock, flashing light and accessories (non replaceable).
WARNING: High risk of electric shock ! Cut off the main power supply from the panel before touching the
fuses (F1 and F2). We recommend to re-check the wiring before replacing any fuse
OFF
Working with 2 motors
(M1 + M2).
Feature "close
immediately" disable.
Push disable.
Extra push of 2
seconds while starting.
Residential feature
disable. Step by step
feature enable also
during opening.
Enable electro-lock on
inputs 10-11 (LOCK ).
Enable use of mechani-
cal safety edge
(N.C. Contact)
Release off

Publicité