2. Difficulties during operation
Situation
Cause
Choke is in "COLD START" position, the
The engine does
exhaust system is blocked no air supply,
not reach the
moving elements worn, ignition spark
speed
weak too large valve clearance, cylinder
head sooty
Operating
Lines to carburetor blocked Spark plug
materials are
spacing incorrect
leaking
Engine-
Wrong choke position,
Noises
Camshaft damaged
Failure of the check valve on the tank cap
Carburetor
leaking
Carburetor gasket is worn out
If no troubleshooting solves the problem, please contact FUXTEC. Only use
original parts approved by FUXTEC. Otherwise, there is a risk of danger.

Customer Service

33.
Have your purchased device repaired only by qualified personnel and only with original spare parts.
This will ensure that the safety of the device is maintained.
Warranty
34.
The warranty period is 24 months from the date of purchase. Please keep your proof of purchase
in a safe place. Excluded from the warranty are wearing parts and damage caused by improper
use, use of force, technical modifications, use of incorrect accessories or non-original spare parts,
and repair attempts by non-qualified personnel. Warranty repairs may only be carried out by
authorized specialist dealers.
Original User Manual FUXTEC FX-EB152/FX-EB162_de_en_fr_rev15
Open choke, replace exhaust system
Check or replace ignition coil, adjust
flywheel, spark plug
Replace the lines and carburetors,
adjust gap dimension
Check/replace camshaft
Replace the fuel filler cap
Replace carburetor or gasket
50