ASTRALPOOLHEAT SERIES · AIR/WATER SYSTEM
Filter Control
ON / OFF.
Comfort Function
Enabled / Disabled
Cool
Enabled / Disabled
Heat+Cool Mode
Enabled / Disabled
Delay Time
XX min.
Sample Time
XX min.
Defrost Mode
1 / 2 / 3
© ASTRALPOOL 2010. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
PARAMETERS OF THE TECHNICAL MENU: CONTINUATION 1
Filter control ON: The heat pump controls the purification
•
pump, control of water flow.
Filter control OFF: The heat pump does not control the
•
purification pump. Will only heat with external filtration.
Comfort function ENABLED: The user may choose
•
between the Comfort and Filtration functions.
Comfort function DISABLED: The heat pump is always
•
functioning in Filtration Mode.
This menu will only appear if the "Purification Control" is
•
activated.
Cool Mode ENABLED: The user may configure the
•
machine to heat or cool.
Cool Mode DISABLED: The user does not have control
•
over the functional mode of the machine, which will be to
heat.
This parameter only appears if the "4-way Valve"
•
parameter is activated in the manufacturer's menu.
Cool+Heat Mode ENABLED: The user may configure the
•
machine to heat and cool.
Cool+Heat Mode DISABLED: The user may configure the
•
machine to heat or cool.
This parameter only appears if the "4-way Valve"
•
parameter is activated in the manufacturer's menu and the
"Cool" parameter is activated.
The time lapse between when the machine should activate
•
and when it really does.
This menu only appears if the "Comfort Function" is
•
activated.
The temperature reading time is 5 minutes or until
•
programmed.
This menu only appears if the "Comfort Function" is
•
activated.
Depending on the installation, one of the following Defrost modes
•
may be selected:
o Fan Stop: By air without fan.
o Air + Fan: By air with fan on.
o Inverter: By inversion of the cycle.
This last mode is only available if the "4-way Valve" parameter is
activated in the manufacturer's menu.
ENGLISH
Page 35 of 246