Dismantling the unit head
CAUTION
The ultra-violet radiation of the UVC lamp can burn your eyes and skin.
Never operate the UVC lamp outside out the casing or in a damaged casing.
Disconnect the unit from the power grid before starting any maintenance work or before re-
placing the UVC lamp.
CAUTION
The quartz glass and UVC lamp could break and cause cuts.
Act with caution when performing work on the UVC clarifier in order to avoid cuts.
Avoid shocks, impacts and abrupt movements to prevent the glass from breaking.
For safety reasons, the UVC lamp can only be turned on when the UVC clarifier is properly
installed in the unit.
Vitronic 11 W
How to proceed:
• Turn the unit head counter-clockwise up to the stop and carefully pull it out of the casing to-
gether with the O ring.
Vitronic 18 W, 24 W, 36 W, 55 W
How to proceed:
• Push down the snap-fit hook, then turn the unit head counter-clockwise up to the stop and
carefully pull the unit head out of the casing.
EN
VTC0003
23