Please check whether or not these
instructions correspond to the device
type.
Adhere to all advice given in these
operating instructions. They include
essential information which must
be observed during the installation,
operation and maintenance. Therefore it is
imperative for the service technician and
the responsible operator / technical staff
to read these operating instructions prior
to installation, start-up and maintenance.
The operating instructions must be
accessible at any time at the place of
application of the ENL 10 Service-Unit .
In addition to these operating instructions,
local or national regulations must be
complied with, if necessary.
Make sure that the ENL 10 Service-Unit is
operated only within the permissible limit
values indicated on the type plate. Any
deviation involves a risk for persons and
materials, and may result in malfunction
and service failures.
If you have any queries regarding these
installation- and operating instructions,
please contact Ingersoll Rand.
Compressed air!
Risk of serious injury or death through contact
with quickly or suddenly escaping compressed air
or through bursting plant components or plant
components which are not secured.
3847892
1. PICTOGRAmS ANd SymbOLS
Observe the installation and operating instructions
Observe the installation and operating instructions
(on the type plate)
General danger symbol (danger, warning, caution)
General danger symbol (danger, warning, caution) for supply voltage and supply voltage carrying
plants components
2. SAFETy INSTRUCTIONS
DANGER
ingersollrandproducts.com
measures:
•
Do not exceed the maximum operating pressure (see
type plate).
•
Only carry out service measures when the system is
pressure less.
•
Use pressure-resistant installation material only.
•
The feed pipe must be tubed firmly. Discharge pipe:
short, fixed pressure hose onto pressure-resistant pipe.
•
Make sure that persons or objects cannot be hit by
condensate or escaping compressed air.
Supply voltage!
There is the risk of an electric shock involving injury or
death when coming into contact with
non- insulated components carrying supply voltage.
measures:
•
During electric installations, all regulations in force
need to be adhered to (e.g. VDE 0100 / IEC 60364).
•
Service measures must only be undertaken when
the system is deactivated.
•
The removed control unit has no IP degree of
protection.
•
All types of electrical works must be carried out by
authorized and qualified personnel only.
DANGER
EN
3