every year beside the indicated periodic maintenance. For this
purpose contact your supplier.
WARNING
Overdue maintenance can cause fire.
WARNING
Always fully disconnect the machine from the mains
before carrying out maintenance jobs as mentioned
below. First read the maintenance regulations at the
beginning of this manual.
The maintenance activities in the table below are strictly
reserved for well trained and authorised service engineers.
Component
Action
Flexible adapters Check for airtightness and damages.
Replace if necessary.
Impellers
Check for dirt. Clean if necessary.
7
TROUBLESHOOTING
If the product does not function (correctly), consult the checklist
below to see if you can remedy the error yourself. Should this
not be possible, contact your supplier.
WARNING!
After switching off the fan, wait at least 30 seconds
before opening the inspection cover.
Symptom
Problem
Motor does not
Fan does not
start.
function.
Motor makes a
Extraction
humming
capacity
sound, but
insufficient or
does not
no extraction
function.
at all.
Motor stops
Fan does not
automatically.
function.
Poor suction.
Extraction
capacity
insufficient or
no extraction
at all.
Vibrations in
Fan running
fan.
unstable.
8
SPARE PARTS
The following spare parts are available:
0507060080/011113/H | SIF-700/900/1200/1500/1800/1900/2000 -|SF 7000/9000/12000/15000/18000/19000/20000
Freq.
Every 12
months
X
X
Possible cause Solution
No mains
Check the mains
voltage.
voltage.
Mains cord
Repair or replace the
defective
mains cord.
Loose contacts.
Repair the contacts.
Thermal relay in
Replace the thermal
system control
relay.
panel defective.
Connection PTC
Repair connection.
to frequency
Refer to manual of
inverter
frequency inverter.
defective.
Motor uses 2
Repair the phase
phases instead
connection.
of 3.
Motor defective. Repair or replace the
motor.
Inverted
Change the direction
direction of
of rotation.
rotation of the
motor.
Inverted
Change the direction
direction of
of rotation.
rotation of the
motor.
Impeller(s) dirty. Clean impeller(s).
Undesired by-
Check the flexible
pass.
adapters.
Imbalance in
Clean the fan.
fan.
Differential
Clean or replace the
pressure of the
filters of the
connected filter
connected filter
system exceeds
system.
capacity of the
fan.
Article no.
Description
SIF-700 / SF-7000
0000102362
Fan wheel
0000102357
Motor 3 kW (4 HP)
SIF-900 / SF-9000
0000102269
Fan wheel
0000102358
Motor 5,5 kW (7.5 HP)
SIF-1200 / SF-12000
0000102363
Fan wheel
0321300140
Motor 7,5 kW (10 HP)
SIF-1500 / SF-15000
0000102364
Fan wheel
0321300130
Motor 11 kW (15 HP)
SIF-1800 / SF-18000
0000102365
Fan wheel
0000102359
Motor 15 kw (20 HP)
SIF-1900 / SF-19000
0000102366
Fan wheel
0000102360
Motor 18,5 kW (25 HP)
SIF-2000 / SF-20000
0000102367
Fan wheel
0000102361
Motor 22 kW (30 HP)
9
DISPOSAL
After life of the product, dispose it of in accordance with state or
local regulations.
EC DECLARATION
CE declaration of conformity for machinery
We, Plymovent Manufacturing B.V., Wezelkoog 11, 1822 BL
Alkmaar, the Netherlands, herewith declare, on our own
responsibility, that the products:
- SIF-700 / SF 7000 LI/RI (Outdoor)
- SIF-900 / SF 9000 LI/RI (Outdoor)
- SIF-1200 / SF 12000 LI/RI (Outdoor)
- SIF-1500 / SF 15000 LI/RI (Outdoor)
- SIF-1800 / SF 18000 LI/RI (Outdoor)
- SIF-1900 / SF 19000 LI/RI (Outdoor)
- SIF-2000 / SF 20000 LI/RI (Outdoor)
which this declaration refers to, are in accordance with the
conditions of the following Directives:
- Machine Directive 2006/42 EC
- LVD 2006/95 EC
- ErP Directive 2009/125/EC
Alkmaar, the Netherlands, November 1, 2013
.
Ir. F. Coehoorn
Vice President Research & Development
An installation is defined as a combination of several finished products
or components that are assembled by an installer at a given place. The
various parts of the installation are intended to operate together in a
particular environment and to perform a specific task. The entire
installation must comply with the relevant directives and standards. The
assembly instructions given by the manufacturer, as well as the whole
method of installation, must be in accordance with good engineering
practices within the context of installations, as well as installation rules.
Considering the above, the installer will be responsible for completing the
installation and issuing the final CE Declaration of Conformity.
EN - 6