G
AERASGARD
Schematic diagram
1 2 3 4
shield
shield
1 2 3 4
Sensor
Plug for
VOC
display
Sensor
CO
2
ON
DIP A
1 2 3 4 5 6 7 8
address
°C
r.H.
VOC
CO ² CO ²
VOC
offset
zero
®
AERASGARD
RCO
®
AERASGARD
RLQ - CO
AERASGARD
®
RFTM - CO
®
AERASGARD
RFTM - LQ - CO
Type ⁄ WG02
RCO
- Modbus
2
R C O 2 M O D B U S
R C O 2 M O D B U S L C D
RLQ - CO
- Modbus
2
R L Q - C O 2 M O D B U S
R L Q - C O 2 M O D B U S L C D
RFTM - CO
- Modbus
2
R F T M - C O 2 M O D B U S
R F T M - C O 2 M O D B U S L C D
RFTM - CO
- Modbus - P
2
R F T M - C O 2 M O D B U S P
R F T M - C O 2 M O D B U S P L C D
RFTM - LQ - CO
- Modbus
2
R F T M - L Q - C O 2 M O D B U S
R F T M - L Q - C O 2 M O D B U S L C D
Note:
ACCESSORIES
KA2 -Modbus
Communication adapter (USB/RS485) for system connection
LA -Modbus
Line termination device (with terminating resistor) as an active bus termination
®
RFTM - LQ - CO
- Modbus
2
R xx CO
Sensor
Plug for
display
Sensor
CO
2
ON
DIP B
ON
DIP A
1 2 3 4 5 6
1 2 3 4 5 6 7 8
mode
address
VOC
°C
r.H.
CO ² CO ²
offset
DIP A: Bus address
DIP B: Bus parameters
(Baud rate, parity ...)
Telegram indicator
1 2 3 4
Reception (LED green)
Error (LED red)
Shielding
Offset correction
LED (internal status)
Reset button
1 2 3 4
- Modbus
Room CO
2
- Modbus
Room air quality (VOC) and CO
2
- Modbus ( - P ) Multifunctional room sensor (with potentiometer)
2
for humidity, temperature and CO
- Modbus Multifunctional room sensor
2
for humidity, temperature, air quality (VOC) and CO
Measuring Range
Humidity
Temperature
–
–
–
–
0...100 % r.H.
0...100 % r.H.
0...100 % r.H.
0...100 % r.H.
0...100 % r.H.
0...100 % r.H.
This unit must not be used as safety-relevant device!
- Modbus
Schematic diagram
2
DIP A: Bus address
VOC
DIP B: Bus parameters
(Baud rate, parity ...)
Telegram indicator
Reception (LED green)
Error (LED red)
Shielding
Offset correction
LED (internal status)
Reset button
VOC
zero
Plug for
display
Sensor
CO
shield
2
ON
DIP B
ON
1 2 3 4 5 6
1 2 3 4 5 6 7 8
mode
address
shield
CO ²
zero
sensor, Deluxe
2
CO
2
–
5000 ppm
–
5000 ppm
–
5000 ppm
–
5000 ppm
0...+50 °C
5000 ppm
0...+50 °C
5000 ppm
0...+50 °C
5000 ppm
0...+50 °C
5000 ppm
0...+50 °C
5000 ppm
0...+50 °C
5000 ppm
15
Sensor
1 2 3 4
CO
shield
ON
DIP B
1 2 3 4 5 6
mode
shield
1 2 3 4
DIP A: Bus address
DIP B: Bus parameters
(Baud rate, parity ...)
Telegram indicator
Reception (LED green)
Error (LED red)
Shielding
Reset button
DIP A
LED (internal status)
Potentio-
meter
sensor, Deluxe
2
content, Deluxe
2
Display
Item No.
VOC
–
1501-61B0-6001-200
–
■
1501-61B0-6021-200
0...100 %
1501-61B1-6001-200
0...100 %
■
1501-61B1-6021-200
–
1501-61B6-6001-200
–
■
1501-61B6-6021-200
with potentiometer
–
1501-61B6-6501-271
–
■
1501-61B6-6521-271
0...100 %
1501-61B8-6001-200
0...100 %
■
1501-61B8-6021-200
1906- 1200- 0000-100
1906-1300- 0000- 100
Rev. 2020 - V24
RFTM - CO
- Modbus - P
2
Plug for
display
2
ON
DIP A
1 2 3 4 5 6 7 8
address
Potentio-
meter
CO ²
zero
content, Deluxe
2
D
D
(B
T
R
E
S
R
L