Troubleshooting; Scrapping - KENT Razor E17 Instructions D'utilisation

Masquer les pouces Voir aussi pour Razor E17:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

TROUBLESHOOTING

Trouble
The motors do not turn on
The dirty water vacuuming is insufficient
The solution flow is insufficient
The squeegee leaves marks on the floor
For further information refer to the Service Manual, available at any KENT Service Center.

SCRAPPING

Have the machine scrapped by a qualified scrapper.
Before scrapping the machine, remove and separate the following materials, which must be disposed of properly according to the
Law in force:
Brush
Pad
Electrical and electronic components (*)
(*)
Refer to the nearest KENT Center especially when scrapping electrical and electronic components.
18
INSTRUCTIONS FOR USE
The power supply cable (21) is faulty or
disconnected from the electrical mains
The recovery water tank (26) is full
The vacuum grid (36) is clogged or the float
is closing
The vacuum hose (22) is disconnected from
the squeegee (11) or it is damaged
The squeegee (11) is dirty, or the squeegee
blades (13, 14) are worn or damaged
The recovery water tank cover (6) is not
properly closed, or the gasket (32) is
damaged
The recovery water tank (6) is dirty (clogged
drain hole)
The solution filter (20) is dirty
There is debris under the squeegee blades
(13, 14).
The squeegee blades (13, 14) are worn,
chipped or torn
909 6311 000(3)2009-11
Possible Cause
Razor E17
Remedy
Replace or connect the cable
Empty
Clean the grid and check the float
Connect
Clean the squeegee or replace the blades
Check and/or clean the seating surface or
replace the gasket
Clean
Clean
Remove the debris
Replace the blades

Publicité

Table des Matières
loading

Table des Matières