OPERATION WITH THERMOREGULATOR
When the power of the water heater is turned on, the software version of the controller is displayed
for 2 seconds. Then the main screen with water temperature, date, time and other additional
information is displayed depending on the current operation mode.
SETTINGS IN THE MAIN MENU
The main menu is entered by pressing ▼button. Navigating in the menu is made by ▼and
▲buttons. To select a setting press 4 button. Scroll the parameters with ▲ and ▼buttons. The
subsequent pressing of 4 buttons enters a current parameter correction mode, with its value
displayed in a red rectangular. The value of the corrected parameter is changed by ▲ and
▼buttons. Once the required value is selected by 4 button, the change is confirmed and the
parameter correction mode is exited. For parameters in the form of ticks (activated/deactivated
state) pressing 4 button directly changes the state of the tick. Changes made are confirmed by pressing 1 button, which
returns the main menu of the controller.
Time and Date - adjusts the date and time of the controller. It is operated by the automatic adjustment function in the
presence of a WiFi module.
Language – sets the language of all messages displayed on the screen of the controller.
Display - changes the display brightness and sets dimming in 30 seconds after the last button is pressed.
Timer1..7 / Program1..7 – sets operation in „Timers" / „Program" mode. Each program or timer can be
activated/deactivated.
Low Cost Tariff - sets the start and end time of the night (second) electricity tariff. The daily (first) tariff covers the rest of
the day. This information is used to maintain electricity meters, and for "Smart Control" mode with "Night tariff" priority.
System Setup – sets the mode of the weekly programmer, heating element power, volume group of the water heater and
enables the "Anti-Legionella" function by ticking the box. For the proper reading of electricity consumed, the power of the
heating element should be set correctly.
Smart Control - additional settings to control algorithms are made "Smart Control" mode. With the "Priority" parameter
you select the method of operation of "Smart Control" mode. By "Correction" parameter you readjust the operation in
"Smart Control" mode with a "Low cost tariff" priority, when the standard setting (+0°), which is the most economical, does
not provide sufficient quantity of warm water. Selecting the tick of "Seasonal" parameter allows for additional heating of
water during the colder months of the year. This is valid for all method of operation of "Smart Control" mode. This option
compensates for the need of more warm water due to the lower inlet (cold) water temperature and most of the heat losses
in the room where the water heater and water piping are installed. For the proper operation of the Smart Control mode, the
power of the heating element and the volume group of the water heater should be set correctly.
New WiFi Router – initializes the WiFi module, if any installed. The connection of a thermoregulator with a WiFi module to
the My Eldom network system for remote control and monitoring is described in the additional manual.
TEMPERATURE SETTING
A set temperature is change by pressing ▲button. The middle display field show the currently set temperature. The
subsequent pressing of ▲ and ▼ buttons changes the adjustment as desired. If no other button is pressed within 5
seconds, the adjustment is saved and then it is proceeded to the main screen. If either ▲or ▼button is held pressed for
longer than 0.7 sec., the value of the set temperature starts increasing or decreasing automatically at a rate of 4 units per
second. The set temperature adjustment range is between 20°C and 75°C.