MAINS CONNECTION
Connect only to a single-phase AC current supply and only to the
mains voltage specified on the rating plate.
Appliances used at many different locations including wet room and
open air must be connected via a residual current device (FI, RCD,
PRCD) of 30mA or less.
Extension cables to the mains must at least be protected from water
spray and contain an earth lead.
Make sure the machine is switched off before plugging in.
If the supply cord of this appliance is damaged, it must only be
replaced by a repair shop appointed by the manufacturer, to avoid
hazardous situations.
WORKING INSTRUCTIONS
Do not direct the air into rooms in an uncontrolled manner.
Before liquids are picked up, always remove the filter bag. Insert
filter for wet operation. Check that the float works and level indi-
cator hose properly. If foam develops or liquid emerges, stop work
immediately and empty the dirt tank.
Not suitable for sweeping up liquids which form a large foam.
When using the blower function, always use a clean hose.
Stirred-up dust can be hazardous to health. Do not use the blower
function in closed rooms.
Only use the appliance if it is in undamaged condition. Never use
the vacuum cleaner without a filter, or if the filter is damaged.
Discard filter elements, filter bags and disposal bags in accordance
with the national regulations.
CONNECTING ELECTRICAL APPLIANCES
The plug socket on the appliance may be used only for the purposes
defined in the usage instructions.
Before plugging an appliance into the appliance socket:
Switch off the vacuum cleaner. Switch off the appliance to be
connected.
CAUTION! Follow the operating instructions and safety instructions
for appliances connected to the power tool socket.
MAINTENANCE, CLEANING AND REPAIR
Always pull out the mains plug before cleaning and maintenance of
the vacuum cleaner.
Only carry out maintenance work described in the operating
instructions.
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
If suction performance drops: Switching on the vacuum cleaner.
Close the nozzles or suction hose opening with the palm of your
hand. Press the button to start filter cleaning three times. The
resulting stream of air removes attached dust from the slats of the
filter elements.
The ventilation slots of the machine must be kept clear at all times.
Clean dust and debris from tool. Keep tool handles clean, dry and
free of oil or grease. Use only mild soap and a damp cloth to clean
the tool since certain cleaning agents and solvents are harmful
to plastics and other insulated parts. Never use flammable or
combustible solvents around tools.
Never spray water on to the upper section of the vacuum cleaner.
Danger for persons, risk or short-circuiting.
Use only AEG accessories and spare parts. Should components
need to be replaced which have not been described, please contact
one of our AEG service agents (see our list of guarantee/service
addresses).
If needed, an exploded view of the tool can be ordered. Please
state the machine type printed as well as the six-digit No. on the
label and order the drawing at your local service agents or directly
at: Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Win-
nenden, Germany.
Storage: The appliance must be stored in a dry place and protected
from frost.
SYMBOLS
CAUTION! WARNING! DANGER!
Always disconnect the plug from the socket before
carrying out any work on the machine.
Please read the instructions carefully before starting the
machine.
Provide adequate ventilation.
Accessory - Not included in standard equipment, available
as an accessory.
for separation of dust with an exposure limit
of greater than 1 mg/m³, (dust class L).
Do not dispose of electric tools together with household
waste material.Electric tools and electronic equipment
that have reached the end of their life must be collected
separately and returned to an environmentally compatible
recycling facility.Check with your local authority or retailer
for recycling advice and collection point.
European Conformity Mark
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product described
under "Technical Data" fulfills all the relevant provisions of the
directives 2011/65/EU (RoHs), 2004/108/EC, 2006/42/EC and the
following harmonized standards have been used:
EN 60335-1:2012
EN 60335-2-69:2012
EN 55014-1:2006+A1:2009+A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006+A1:2009+A2:2009
EN 61000-3-3:2008
Winnenden, 2014-05-23
Alexander Krug / Managing Director
Authorized to compile the technical file
Techtronic Industries GmbH
Max-Eyth-Straße 10, 71364 Winnenden, Germany
Deutsch

English

13
D GB

Publicité

Table des Matières
loading

Table des Matières