Télécharger Imprimer la page

Brita PURITY 450 Steam Mode D'emploi page 32

Masquer les pouces Voir aussi pour PURITY 450 Steam:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
If this button is pressed (> 10 seconds), the data set on initial
installation will be accepted again, and the capacity, bypass
setting and input date are all updated.
Note: This automatically sets the monthly limit to 12 months.
Note: If no input is made within 30 seconds, the display will return to standby or operating mode
without accepting amended parameters.
Insert the display unit from the front at a height of approx. 10 mm and slide down. The loops on the
display part must be inserted in the grooves on the measuring head.
6.1 Removing the Filter Cartridge
Switch off power supply to the terminal device (remove plug).
Close inlet valve
Place the flushing hose in a bucket and remove pressure from the filter system by opening the
flush valve. Catch the escaping water in a bucket.
Note: If the escaping water is more than 1 litre, the inlet valve
blocked with scale.
Place the pressure vessel lid
Note: Do not turn the lid horizontally on its head.
EN
Stand on the kick loops
the mantle handles
Take your feet off the kick loops
the mantle handles
Remove exhausted filter cartridge
Place the exhausted filter cartridge
remaining water (> 5 min.).
Lock the exhausted filter cartridge
cartridge and return in the original packaging to the appropriate BRITA address listed on the
back of the cover.
6.2 Inserting the Filter Cartridge
30
at inlet hose
.
7
6
Stand on the kick loops
lid
by pressing the lock
3
vertically on both lid handles
3
with both feet while turning the pressure vessel
12
as far as it will go.
16
and press the pressure vessel
12
.
16
2
2
2
Check the connector seat of the filter cartridge O-ring
lid
for dirt and damage.
1
Check that the O-ring seal of the filter cartridge
groove and also check for dirt and damage.
Note: The cartridge seat has been lubricated with food-safe lubricant at the
factory.
Place the new filter cartridge
Stand on the kick loops
clockwise until the mantle handle
with both feet while opening the pressure vessel
12
and turning it anticlockwise as far as it will go.
15
from the pressure vessel
in the sink with the connection facing down to drain the
with the transport protective cap
in the pressure vessel
2
with both feet, lift the pressure vessel
12
is over the kick loops
16
is not completely closed or is
7
.
20
anticlockwise by
1
down with both hands on
1
.
1
of the new filter
18
in the pressure vessel
2
is correctly seated in the
2
.
1
1
.
12
turning it

Publicité

loading

Ce manuel est également adapté pour:

Purity 600 steamPurity 1200 steam