effegibi Nuvola Touch Manuel D'utilisation Et D'entretien page 49

Générateurs de vapeur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NUVOLA TOUCH OperATiNg ANd mAiNTeNANCe mANUAL
pLeASe NOTe: the information in the table below and the action to take is intended for
the use of the assistance centre personnel and others qualified to install/maintain the
equipment.
error message
Critical errors
Non-critical errors
For any situations not covered in this table, consult your approved assistance centre or contact the company
direct.
The data and features referred to are not binding on EFFEGIBI and the company reserves the right to make any appropriate changes without having to give prior warning or replace this manual.
meaning
No software dialogue
Lack of
with an element alre-
communication with
ady recognised.
1 or more devices.
The control panel is
Lack of
not in dialogue with
communication with
the other electronic
1 or more devices.
elements.
New peripheral device
recognised.
Temperature probe is
broken.
Boiler full too soon.
The boiler filled
too quickly during
initial rinsing or final
emptying.
Boiler not yet full.
The boiler didn't fill
within the prescribed
time
initial rinsing or final
emptying.
Boiler not yet empty.
The water level in
the boiler remained
too high for too long
during initial rinsing or
final emptying.
error
Cause
One of the devices is
not receiving power
or is not connected.
One of the devices is
not receiving power
or is not connected.
A new component
has been connected
to the product.
Problem with the
probe.
Outlet valve not
working.
Lack of water in the
system or the inlet
limit
during
valve filter is blocked.
Outlet
valve
working.
eN
Solution
1. Check the device
connections.
2. Run the start-up
sequence.
1. Check the device
connections.
2. Run the start-up
sequence.
1. Check connections
and power cabling.
2. Run the start-up
sequence.
Replace panel.
1. Check that the
outlet path is clear.
2. Check that the
steam pipe is not
obstructed, bent or is
not siphoning.
3. Clean the outlet
valve.
1. Check that the
water tap is turned
on.
2. Check that there is
water in the system.
3. Check that the
filter at the entrance
to the inlet valve is
not blocked.
not
1. Check that the
outlet path is clear.
2. Check that the
steam pipe is not
obstructed, bent or is
not siphoning.
3. Clean the outlet
valve.
47