RZ_prima 5+.qxp_Text_EN_prima 5 PLUS 21.12.18 12:12 Seite 13
3
Before using the device
3.1 Delivery status >>
page 2):
A
Pump handle
B
Pump body
C
Hose connection
D
Spray tube holder 1
E
Spray tube holder 2
F
Fill level control
G
Base ring
H
All-plastic quick closure valve
I
Plastic spray tube with nozzle
4
Technical data
Pressure Sprayer: prima 5 Plus; Article number: 000106.0000
Permissible positive operating pressure 3 bar / max. filling quantity: 5 litres / total filling quantity:
8 l / permissible operating temperature: 0°C – 40°C / empty weight: 1.4 kg / total weight: 6.4 kg /
reaction force on the nozzle: < 5 N / spray tube holder / piston-type pressure gauge with built-in
safety valve / container material/pump material: polyethylene
Notes regarding the nozzle
Spray
Bore hole min.
pattern
clearance
hollowcone
5
Assembly >> Figures
6
Commissioning
6.1 Filling container with water, applying pressure & checking safety valve
"L" >>
6.2 Venting container, emptying water & filling with plant protection
product >>
ATTENTION
must be observed.
6.3 Applying pressure and spraying >>
Lock the pump handle "A" after the pumping process by press the pump all the way down and
turning the pump handle in a clockwise direction beyond the resistance until it stops.
Press down the control lever on the quick closing valve; this triggers the spraying process.
Pump when the spray pressure decreases or the yellow marking on the piston gauge is no longer
visible. Do not exceed the permissible operating pressure of max. 3 bar.
Yellow marking:
You are working with the optimum
spray pressure.
The device is shipped as standard as follows
Sprayangle
in l/min at pressure/bar
1 mm
0-60°
0,33/0,43/0,49/0,54
1,5 / 2,0 / 2,5 / 3,0
–
1
–
Figures
7
5
Figures
–
8
11
Information from the spraying agent manufacturer and dosage instructions
J
40 cm extension tube
K
Carrying straps
L
Piston -type pressure gauge with built-in
safety/pressure relief valve
M
Filling funnel
N
1 x user manual and product information
Any accessory parts are packaged separately as
part of the delivery.
Flow rate
Material
brass
4
12
–
18
Figures
Red marking: If you exceed the
optimum spraying pressure, do not
continue to SPRAY, vent the device.
13
(see figure on
Optim. pressure
Filter
1,5 - 3 bar
Serie