When you contact the after-sales service of your distributor or your store, give him the com-
plete reference of your device (commercial name, type and serial number). This information
appears on the visible descriptive plate behind the device.
6. CLEANING AND MAINTENANCE
- Let cool completely the device and the oil before any technical intervention or cleaning.
- Unplug the machine and remove the heating elements unit
- For cleaning, only use non-abrasive products, clean regularly the external walls of your de-
vice with warm water and wash liquid: avoid the abrasive towelling. Rinse your device with a
wet sponge.
- Caution : do not damage the heating element wires during cleaning
- Never clean the device under a water jet
7. TECHNICAL SPECIFICATIONS
Models
Power
Outside dimensions
Volume
No element
Volatge
Ampere
Weight
Maximum charges
(Kg)
The machine is delivered with a cord fitted with 5 wires
Wires colours correspondence
The equipotential connection marked by this symbol
potential conductive connection of your installation by means of a minimum conduction of a
2.5 mm² section.
RFE 16 C
12 kW
400 x 660 x 980 mm
16 L
3
380-415 V 3 N ~
17 A/ Phase
34 Kg
4
Phase 1
Phase 2
Phase 3
Neutral
Earth
RFE 20 C
12 kW
400 x 660 x 980 mm
2 x 10 L
2
380-415 V 3 N ~
16 A/ Phase
38 Kg
2 x 1.5
Brown
Black
Grey
Blue
Yellow-Green
must be linked with the equi-
19