Velleman WS3080 Mode D'emploi page 8

Avec émetteur solaire et interface pc
Masquer les pouces Voir aussi pour WS3080:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
reset max
reset min
UV index
Refer to §8.2 for more information.
high alarm
reset max
Wind
wind speed
speed unit
high alarm
direction alarm
reset max
Light
light unit
high alarm
reset max
Rain
display mode
unit
high alarm
reset max
reset total
Use the HISTORY button [f] to enter the base station memory.
Note: the default interval for data memory is 30 minutes. This interval can only be changed via the
software (refer to the section PC connection).
Use the  [d] button to scroll down through the memory, use the  [c] to scroll up.
Note: when the end of the memory is reached, the base station returns to normal display.
To clear the complete memory, press the ENTER button [b]. The word CLE [4] and the memory indicator
[5] will start flashing. Press and hold the ENTER button [b] for ±3s to erase the memory.
Note: to save a copy of the memory on a PC, refer to the section PC connection.
V. 01 – 21/06/2013
WS3080
the alarm icon
appears.
(both outdoor temperature [12] and max icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
(both outdoor temperature [12] and min icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset min value to current
measurement
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
(both UV index [15] and max icon (between [14] and [15]) are flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
select between average or gust wind speed (default = average)
select between km/h, mph, m/s, knots or bft (Beaufort) (default = mph)
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
set the wind direction alarm
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
(both wind speed [14] and max icon (between [14] and [15]) are flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
select intensity unit between fc and lux
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
(both light intensity [17] and max icon (between [14] and [15]) are
flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
select between 1h, 24h, 1 week, 1 month or total
select between mm and inch (default = mm)
set the high alarm level
Press the ALARM ON/OFF button to enable/disable the alarm. When enabled,
the alarm icon
appears.
(both rain value [16] and max icon (between [14] and [15]) are flashing)
press and hold the ENTER button for ±3s to reset max value to current
measurement
(the rain value [16], TOTAL and CLE [4] are flashing)
press and hold the ENTER button for ±3s to reset TOTAL value to current
measurement
8
©Velleman nv

Publicité

Table des Matières
loading

Table des Matières