6.0.0
TECHNICAL DATA
6.1.0
POWER UNIT
System connection
Control voltage
System cable
Light connection
Heater connection
Thermal release
Temperature sensor
Power input
Ambient conditions
Housing
Fixing
Dimensions: L x W x H
Weight
WE DO IT FIRST.
INSTRUCTION MANUAL
MODE D'EMPLOI
For 3 x 400 V~ 50 Hz with L1-L2-L3-N-PE; Housing only
for standardised service connection with fusing and
residual-current circuit-breaker. The main switch must
have a minimum contact gap of 3 mm.
Extra-low voltage 5 V= and 12 V=
Typically 5 x 2.5 mm²
For 2- (3-) pole connection of the 230 V incandescent
lamp(s); max. 100 W
3 x 400 V~ 5-pole, up to max. 3 kW depending on the
heater output, and/or 14 A per phase
Integrated into the heater sensor as overtemperature
protection; release temperature 139 ° C
2-pole; semi-conductor sensor -9 ° to 140 ° C
Heater:
max. 3 x 3 kW (heater)
Light:
max. 100 W
0 ° C to max. 50 ° C, max. 95 % rel. humidity, not
condensating!
IP54; CAT2
Screwing-on by means of 4 M3 fixing holes
250 x 165 x 55 mm
950 g
26/42