INSTALLATION OF THE
LIGHTING SYSTEM
When installing the lighting system, please
make sure that it is installed at the greatest
possible distance from the sauna heater
(preferably in the opposite corner), that the
sauna light conforms to the requirements of
the "splash-proof" degree of protection and is
suitable for an ambient temperature of
140 ° C. The sauna lighting system can then
be connected to the power unit.
4.5.0
FINAL INSTALLATION OF ALL
MODULES AND CABLES
Upon installation, all lines are fed into the
power unit through the respective holes.
Subsequently, all lines are connected in
accordance with the terminal diagram.
ATTENTION!
According to standard EN60335, light and
oven have to have a separate power
supply.
Since the sauna control unit is powered
via the light supply, it is crucial that the
light supply is connected!
WE DO IT FIRST.
INSTRUCTION MANUAL
MODE D'EMPLOI
5.0.0
The connector pin assignment is
always based on a left-to-right
counting mode!
NOTE!
Disconnect all poles until all work has
been completed and fuse prior to re-
connecting!
The connection of the sauna control unit
must be completed by a licensed
specialist (electrician) in accordance with
the relevant standards. The cables used
must comply with the relevant statutory
provisions.
NOTE!
In order to meet the disconnection from
supply conforming to the standards, a
switch between the sauna heating unit
and the fuse box has to be installed which
ensures an all-pole disconnection.
The switch contact opening has to be at
least 3mm in order to meet the
requirement of a "full offswitch".
5.1.0
ELECTRICAL
CONNECTIONS
TERMINAL OVERWIEW
Minimum cross section in mm²
Connected
load in kW
Supply
conductor
6
5 x 1,5
7,5
5 x 2,5
9
5 x 2,5
24/42
(copper)
Heater
System
line
fusing
5 x 1,5
3 x 16 A
5 x 1,5
3 x 16 A
5 x 1,5
3 x 16 A