Problem
Water flows on the
ground.
The temperature in
the appliance is too
low.
The temperature in
the appliance is too
high.
7.1 Replacing the lamp
2
1
7.2 Closing the door
1.
Clean the door gaskets.
2.
If necessary, adjust the door. Refer
to "Installation".
Possible cause
Products prevent that wa-
ter flows into the water
collector.
The melting water outlet
does not flow in the evap-
orative tray above the
compressor.
The temperature regula-
tor is not set correctly.
The temperature regula-
tor is not set correctly.
The door is not closed
correctly.
The product temperature
is too high.
Many products are stored
at the same time.
There is no cold air circu-
lation in the appliance.
The appliance is equipped with a longlife
LED interior light.
1.
2.
3.
4.
5.
6.
7.
3.
Solution
Make sure that products
do not touch the rear
plate.
Attach the melting water
outlet to the evaporative
tray.
Set a higher temperature.
Set a lower temperature.
Refer to "Closing the
door".
Let the product tempera-
ture decrease to room
temperature before stor-
age.
Store less products at the
same time.
Make sure that there is
cold air circulation in the
appliance.
Disconnect the appliance.
Push the movable part to unhook the
lamp cover (1).
Remove the lamp cover (2).
If needed replace the lamp with a
light of similar characteristic and pow-
er. It is suggested to use Osram PAR-
ATHOM SPECIAL T26 0.8 Watts.
Install the lamp cover.
Connect the appliance.
Open the door. Make sure that the
lamp comes on.
If necessary, replace the defective
door gaskets. Contact the Service
Center.
ENGLISH
25