Index
1 General information.........................................2
2 Mounting to Wall..............................................3
3 Mounting the relay unit....................................4
4 CTx electrical connections..............................5
1
G
ENERAL INFORMATION
This manual includes information on the installation
of Coin Timers with display for showers: CT4Xw,
CT6Xw, CT8Xw here onwards indicated by the
term CTx. For configuration and use please see the
appropriate manual.
The CTx Coin Timer is a coin or token timer useful
for offering one or more pay shower services.
The CTx comes with a separate relay unit with
12Vdc outputs for directly controlling the solenoid
valves which regulate the flow of water.
1.1 Symbols used in the manual
Parts of the text which are of particular importance
in regards to the safety or proper use of the product
are indicated by the following symbols:
Risk of danger or injury to persons if
instructions or the necessary precautions are
not followed.
Important information on product use.
1.2 CTx Versions
The CTx comes in 2 versions, which can be
selected upon ordering:
1. CTx version 100-240V is directly powered
with a voltage of 100-240V. When used for
showers, regulation IEC60364-7 allows it to
be installed in "Zone 3" on the condition that
the device is powered by a residual current
circuit breaker with a 30mA threshold. For
greater safety we advise that this version be
installed in "Zone 4", and that a power
supply 12Vdc be used in "Zone 3". See Fig.
1 and Fig. 2 for identification of the zones.
2. CTx version 12Vdc is powered with a 12Vdc
voltage. This version is suitable for installing
the CT1w in places where a safety extra-low
F
E
D
AVERO
LECTRONIC
ESIGN
HOWERS
Pag. 3 / 36
voltage
If used for showers, regulation IEC60364-7
allows the CT1w to be installed in "Zone 3".
It comes provided with an external power
supply with 100-240V input, which should be
placed inside an electrical panel in "Zone 4"
where the use of such voltage is permitted. A
power supply device placed in "Zone 4"
should, nevertheless, be powered by a
residual current circuit breaker with a 30 mA
threshold.
1.3 Technical features
Size and Weight CTx.....:
Size and Weight
relay unit.......................:
Power supply CTx
on version 100-240V...: 100-240Vac, 50-60Hz,
on version 12Vdc........: 12Vdc 1.3A
External power supply, furnished with CTx version
12Vdc:
Input..........................: 100-240Vac, 50-60Hz,
Output.......................: 12Vdc 1.3A
Power supply relay unit: 100-240Vac, 50-60Hz,
Temperature operating..: 0 ... +45 °C
Temperature storage.....: -20 ... +85 °C
Relative humidity
without condensation....:
Output for Solenoid
valve...............................:
lnternational Protection Rating CTx
on standard version...: IP30
on version with option
"Protection from rain
and splashing water".: IP34
International Protection
Rating
relay unit.....................: IP56
00182-M03-03-ML - Manuale installazione CT4xw-6xw-8xw
ENGLISH
is
required.
(Width x Height x Depth)
22,5 x 26,0 x 14,0 cm,
5,2kg
(
Width x Height x Depth
23,5 x 30,0 x 12,5 cm,
1,9kg
0.35A
0.35A
2.5A
20 - 90% (operating
and storage)
12 Vdc, 0,8A max