SUCO 0530 Série Mode D'emploi page 2

Publicité

Connexions électriques
DIN EN 175301-803-A
M 12–DIN EN
61076-2-101-A
2
2
3
PE
1
3
Broche
Assignation
Broche
Assignation
1
U
1
U
v+
v+
2
Gnd
2
nc
3
Out
3
Gnd
PE
4
Out
IP65
IP67
h ~ 60 mm
h ~ 54 mm
(sans connecteur)
h ~ 76 mm
(sans connecteur)
d ~ ø 30 mm
d = ø 22 mm
AMP Superseal
DEUTSCH DT04-4P
Broche
Assignation
Broche
Assignation
1
Out
1
Gnd
2
Gnd
2
U
v+
3
U
3
nc
v+
4
Out
IP67
IP67, IP6K9K
X ~ 73 mm
X ~ 74
d ~ ø 30 mm
d ~ ø 23 mm
Câble
1: rouge
2: blanc
3: noir
Câble
Assignment
053x
Rouge
U
v+
Blanc
Out
Noir
Gnd
IP67
x ~ 44 mm
(+ 20 mm protège câble)
d ~ ø 22 mm
Montage
Mécanique, hydraulique, pneumatique:
Visser le pressostat électronique sur le raccordement de pression à l'aide
d'une clé plate de 22 (suivant DIN 894 ou similaire).
Pour assurer l'étanchéité du montage, utiliser un joint approprié au fi letage
retenu. Pour les fi letages avec joint intégré, aucun système d'étanchéité
supplémentaire n'est nécessaire.
Raccordement électrique:
Vérifi er que le positionnement de joint de connecteurs est correctement
positionné, et que le presse-étoupe Pg (pour DIN EN 175301-A) est
parfaitement mis en place, sans quoi l'indice de protection IP65 ne pourra
être assuré
Attacher une attention particulière lors du câblage du connecteur DIN EN
175301-A:
– respecter le schéma de connexion
– vérifi er l'absence d'écrasement sur le chemin de câble
– presse-étoupe Pg vissé avec un couple de 20 cN.m
Démontage
Lors du démontage du pressostat électronique, veuillez respecter les
points suivants:
• Avant de démonter le pressostat électronique, éliminer toute pression
dans le circuit.
• Respecter toutes les règles de sécurité applicables en vigueur.
• Dévisser le pressostat électronique du raccordement de pression à
l'aide d'une clé plate de 22 (suivant DIN 894ou similaire).
Marquage CE
Les pressostats électroniques
SUCO
tombent
sous
la
Directive
CEM
2014/30/EU.
Les déclarations de conformité
CE ont été établies pour les
pressostats électroniques et
sont disponibles sur simple
demande, ou téléchargeables
directement
sur
notre
site
internet. Les appareils portent
le marquage CE.
Explication des symboles:
Nota,
Attention
Recyclable
remarque
Nos produits étant continuellement en développement, nous nous
réservons le droit d'apporter toutes modifi cations sans préavis.
Electrical connections
ISO 15170-A1-4.1
DIN EN 175301-803-A
1
4
PE
4
2
Broche
Assignation
Pin
1
U
1
v+
2
Gnd
2
3
Out
3
4
nc
PE
IP67, IP6K9K
h ~ 65 mm
h ~ 60 mm
(without coupler socket)
h ~ 76 mm
(without coupler socket)
d = ø 27 mm
d ~ ø 30 mm
DEUTSCH DT04-3P
AMP Superseal
Broche
Assignation
Pin
A
U
1
v+
B
Gnd
2
C
Out
3
IP67, IP6K9K
x ~ 74 mm
X ~ 73 mm
d ~ ø 23 mm
d ~ ø 30 mm
Cabel Connection
(1) Connexion électrique
(2) Raccord Hydraulique /
pneumatique
Kabel
Red
White
Black
x ~ 44 mm
(+ 20 mm cable gland)
d ~ ø 22 mm
Installation
Removing
CE Mark
Key to drawings:
Caution
Subject to technical changes without notice.
Danger
M 12–DIN EN
ISO 15170-A1-4.1
61076-2-101-A
1
4
2
2
3
1
3
4
2
Assignment
Pin
Assignment
Pin
U
1
U
1
v+
v+
Gnd
2
nc
2
Out
3
Gnd
3
4
Out
4
IP65
IP67
h ~ 54 mm
d = ø 22 mm
DEUTSCH DT04-4P
DEUTSCH DT04-3P
Assignment
Pin
Assignment
Pin
Out
1
Gnd
A
Gnd
2
U
B
v+
U
3
nc
C
v+
4
Out
IP67
IP67, IP6K9K
X ~ 74
d ~ ø 23 mm
1: red
2: white
3: black
(1) Hydraulic / pneumatic
connection
(2) Electrical connection
Assignment
053x
U
v+
Out
Gnd
IP67
Mechanical, pneumatic, hydraulic:
Screw the electronical pressure switch into the pressure connection
provided using an open-jaw spanner of 22 AF size (as per DIN 894 or
similar).
To seal the system, use a proper gasket relating to the individual thread.
For threads with integrated sealing ring no additional sealing is necessary.
Electrical:
Ensure that the position of the seal of individual connectors is correctly
mounted and the Pg gland (at DIN EN175301- A) is properly fi tted, as
otherwise the IP-class of the enclosure cannot be achieved.
Pay particular attention while wiring the connector DIN EN 175301-A:
– cable connections as per diagram
– cables routed without crushing
– Pg gland screwed with ca. 20 cN.m
Please bear in mind the following when removing the pressure switch:
• Before the electronic pressure switch is removed, the system must be
depressurized
• All the relevant safety regulations must be complied with.
• Unscrew the pressure switch out of the pressure connection using an
open-jaw spanner of 22 AF size (as per DIN 894 or similar).
Electronic pressure switches
from SUCO fall under the
2014/30/EU EMC Directive.
EC declarations of conformity
have been issued for the
electronic pressure switches
are available on request or
can be downloaded from
our website. The devices are
denoted by a CE mark.
Note
Recycling
Elektrische Anschlüsse
DIN EN 175301-803-A
1
PE
3
Assignment
Pin
Assignment
U
1
U
v+
v+
Gnd
2
Gnd
Out
3
Out
nc
PE
IP67, IP6K9K
IP65
h ~ 65 mm
h ~ 60 mm
(ohne Gerätesteckdose)
h ~ 76 mm
(mit Gerätesteckdose)
d = ø 27 mm
d ~ ø 30 mm
AMP Superseal
Assignment
Pin
Belegung
U
1
Out
v+
Gnd
2
Gnd
Out
3
U
v+
IP67, IP6K9K
IP67
x ~ 74 mm
X ~ 73 mm
d ~ ø 23 mm
d ~ ø 30 mm
Kabelanschluss
1: rot
2: weiß
3: schwarz
Kabel
Belegung
Rot
U
v+
Weiß
Out
Schwarz
Gnd
IP67
x ~ 44 mm
(+ 20 mm Knickschutz)
d ~ ø 22 mm
Einbau
Mechanisch, pneumatisch, hydraulisch:
Drehen Sie den Druckschalter mit einem Maulschlüssel der Schlüsselweite
22 (nach DIN 894 o.ä.) in den vorgesehenen Druckanschluss.
Zum Abdichten des Systems verwenden Sie eine für das jeweilige
Gewinde geeignete Dichtung. Für Gewinde mit integriertem Dichtring ist
keine zusätzliche Dichtung notwendig.
Elektrisch:
Achten Sie auf die ordnungsgemäße Lage der Dichtungen der jeweiligen
Steckverbindung und auf eine sachgemäße Montage, da sonst die IP-
Schutzart nicht erreicht wird.
Bitte beachten Sie beim Anschlagen der Leitung in der Gerätesteckdose
DIN EN 175301-A:
– Verkabelung nach Anschlussbild
– Quetschfreie Kabelführung
– Pg-Verschraubung (mit ca. 20 cN.m) anziehen.
Ausbau
Beachten Sie folgende wichtige Punkte beim Ausbau des Druckschalters:
• Das Drucksystem, aus dem der Druckschalter ausgebaut werden soll,
muss sich im drucklosen Zustand befi nden.
• Es müssen alle relevanten Sicherheitsbestimmungen beachtet werden.
• Drehen Sie den Druckschalter mit einem Maulschlüssel der
Schlüsselweite 22 (nach DIN 894 o.ä.) aus dem Druckanschluss.
CE Kennzeichnung
Elektronische
von SUCO fallen unter die EMV-
Richtlinie 2014/30/EU. Für die
elektronischen
ist
eine
EG
erklärung
diese kann angefordert oder
von
unserer
heruntergeladen
Die Geräte sind mit dem CE-
Zeichen gekennzeichnet.
Zeichenerklärung:
Danger
Achtung
Hinweis,
Bemerkung
Technische Änderungen zur Produktverbesserung vorbehalten.
M 12–DIN EN
ISO 15170-A1-4.1
61076-2-101-A
1
4
2
2
3
1
3
4
2
Pin
Assignment
Pin
Assignment
1
U
1
U
v+
2
nc
2
Gnd
3
Gnd
3
Out
4
Out
4
nc
IP67
IP67, IP6K9K
h ~ 54 mm
h ~ 65 mm
d = ø 22 mm
d = ø 27 mm
DEUTSCH DT04-4P
DEUTSCH DT04-3P
Pin
Belegung
Pin
Belegung
1
Gnd
A
U
2
U
B
Gnd
v+
3
nc
C
Out
4
Out
IP67, IP6K9K
IP67, IP6K9K
X ~ 74
x ~ 74 mm
d ~ ø 23 mm
d ~ ø 23 mm
(1) Hydraulischer /
pneumatischer Anschluss
(2) Elektrischer Anschluss
053x
Druckschalter
Druckschalter
Konformitäts-
ausgestellt
und
Internetseite
werden.
Recycling
Gefahr
1
3
v+
v+

Publicité

loading

Ce manuel est également adapté pour:

0530053105320533