Astralpool EVOLine 6 Manuel D'instructions page 18

Masquer les pouces Voir aussi pour EVOLine 6:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
Problem:
Observation:
Possible cause
1. The wrong mode bas been selected
2. The controller is out of order
3. The 4-way valve is out of order
Problem:
Observation:
Possible cause
1.Wrong setting of parameters
2. Pressure switch out of order
3. Electrical failure
Problem:
Observation:
Possible cause
1. Condensation due to atmospheric humidity
2. Water leak
Problem:
Observation:
Possible cause
1. Insufficient air inflow
2. High water temperature
3. lncorrect setting ofautomatic defrost control
4. The 4-way valve is out of order
5. Not enough refrigerant
the heat pump works normally but the water is cooling down instead of heating up
the screen displays the temperature but no error codes
1. Verify the parameters, select the correct mode
2.Check the voltage in the electrical wiring to the 4-way valve. lf
no electric potential is measured, replace the controller
3. Check the voltage in the electrical wiring to the 4-way valve. If
electric potential is measured, replace the coil.
If the problem persists, have the heat pump checked by a refrigera-
tion technician
the heat pump doesn't stop
the screen displays the temperature but no error codes
1. Check the set parameters and adjust them if necessary
(settingsjust above the capacity of the heat pump)
2. Check operation of the pressure switch by turning off the filter
pump and restarting it. If the heat pump doesn't react to this, the
pressure switch must be adjusted or replaced.
3. Contact your installer
there's an amount of water under the heat pump
1. No action required
2. Try to localize the leak and check for the presence of cblorine
in the water. Ifthat is the case , the heat pump must be temporarily
replaced during repair.
abnormal amount of ice formed on the evaporator
the evaporator is for the most part covered in ice
1. Check the location of the heat pump and remove any dirt
that could be present on the evaporator
2. If the pool water is already qui te hot (warmer than 29?), the
probability ofice formation increases.
Lowering the set temperature is a possible option
3. Check the setting of the defrosting fonction together with
your installer.
4. Check the voltage in the electrical wiring to the 4-way valve.
If electric potential is measured, replace
the coil. If the problem persists, have the heat pump checked
by a refrigeration technician.
5.Have the heat pump cbecked by a refrigeration technician.
Solution
Solution
water leak
Solution
Solution
18
EN

Publicité

Table des Matières
loading

Table des Matières