Parameter table overview (2/2)
Parameter
Manual Description
Setting ofheat exchange ice
19
protection Tout
( too low water flow)
Protection setting of
20
In-Out water temperature
Protection water outlet temp.
21
heating
Time delay of compressor start
22
(after filter pump start)
Time delay offilter pump stop
23
(after compressor stop)
Setting Ambient temp. to Start
24
bottom heater
Setting Ambient temp. to change
25
fan speed
26
Change Fahrenheit/C(0=C/1 =F)
27
Factory reset
Remarks: To change the factory default via the phone, password is required and only available for
technician.
* Run 5m in /2 hr = fi lt er pump runs 5 min every 2 hours checking inlet temp., will run for 5 min, in this
period will disregard the flow switch.
** (O = m a nua l, in manual parameter 13 and 14 is enabled/ l=auto ma tic , in Automatic parameter 13
disabled only Parameter 12 & 14 is valid.)
System measure value overview (2)
Parameter
T0
T1
T2
T3
T4
Compressor receiver temp.
T5
T6
T7
Remarks: " ┌ " =" T", e.g. " ┌ 0" = T 0".
App Description
Protection water outlet
Protection In-Out water
Protection water outlet
Delay of compressor start
Delay of filter pump stop
Bottom Heater Start
Setting Fan Speed Temp
Description
Water inlet temp.
Water outlet temp.
Evaporator coi! temp.
Ambient temp.
Opening ofEEV
Not used
Not used
Range
3 ~ 20°C
temp. cooling
5 ~ 20°C
20~ 90°C
temp. heating
5 ~ 99S
5 ~ 99S
0 ~ 20°C
5 ~ 40°C
Fahrenheit /C
0(C)/l(F)
0(Reset)/
Factory Reset
l(Existing
Setting)
Range
-9 ~ 99°C
-9 ~ 99°C
-9 ~ 99°C
-9 ~ 99°C
-9 ~ 99°C
10 ~ 50 (1 =10P)
-9 ~ 99°C
-9 ~ 99°C
15
EN
Default
Remark
5°C
Adjustable
13°C
Adjustable
60°C
Adjustable
60S
Adjustable
30S
Adjustable
7°C
Adjustable
27°C
Adjustable
0
Adjustable
1
Adjustable
Remark
Measured Value
Measured Value
Measured Value
Measured Value
Measured Value
Measured Value
Measured Value
Measured Value