Parameter table overview (1/2)
Parameter
Manual Description
00
Temp. Setting Cooling
01
Temp. Setting Heating
02
Time between defrosting cycles
Evaporator temp.
03
Defrost start
Evaporator temp.
04
Defrost stop
05
Defrosting time
06
Number of Refrigerant system
07
Power-offmemory setting
Type of unit
08
(0=on l y cooling /1= heat pump /
2=ET. Heating /3=hot water)
Filter pump setting
(0=al ways running / 1 =fi l ter
pump stop 30sec after compressor,
09*
filter pump start every 2 hours
checking inlet temp., will run for 5
min, in this period will disregard
the flow switch)
Temp. Setting for running
10
AUTO Mode
11
Delta Temp. Start-Stop
4 way valve direction
12
(0=heating / 1=cooling)
Water free zing protection setting
13
ambient temperature or Function
Setting lnlet water Anti-freezing
14
Parameter
Start the heat pump and press button «-» and button
«TIMER» on the control display together for 3 seconds
to activate the control display WIFI. WIFI icon starts
blinking and search the WIFI nearby.
App Description
Temp. Setting Cooling
Temp. Setting Heating
Time between Defrosting
Evaporator Temp. Defrost
start
Evaporator Temp. Defrost
stop
Defrosting time
Number of Refrigerant
system
Power-offMemory Setting
Type of Unit
Filter Pump Setting
Temp. setting AUTO
Delta Temp. Start-Stop
4 way Valve Direction
Water freezing protection
Air
Anti-freezing
(ln let-water)
14
Range
Default
8~ 37°C
12°C
8~ 40°C
28°C
10~ 90Min
45Min
-30 ~ 0°C
-7°C
2~ 30°C
13°C
1~ 12Min
8Min
1 ~ 4
1
0(No)/l(Yes)
1 ( Yes)
1
0 ~ 3
( heat pump)
0 ~ I
0
8 ~ 40 °C
28°C
1 ~ 20 °C
2°C
0( heating) /
0
1 (cooling)
0 ~15℃
0°C
2 ~14℃
4°C
EN
Remark
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable