Télécharger Imprimer la page

AQUALUX 106454 Mode D'emploi page 4

Publicité

Les langues disponibles

Les langues disponibles

This manual provides information about the installation, the use and maintenance
of your pump.
This pump is designed to ensure the flow of clean water and disinfected in a private swimming pool
filtration circuit. Any other application will invalidate any warranty and / or appeal with the supplier.
The water temperature should not exceed 35 ° C.
HYDRAULIC CURVES
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
Disconnect the pump before any intervention
II INSTALLATION
- Protect the electrical circuit to the pump by a 30mA RCD, ensuring the proper grounding of
your installation. if in doubt consult a qualified professional.
- Position the pump horizontally at 3.50 m over the basin, below the level of water in a dry, well
ventilated, protected from rain. Leave a space of 30 cm behind the fan cover.- Ensure the accessibi-
lity of the strainer basket for regular cleaning.
- Set the pump on a solid base (concrete base filter, plank) using 2 screws adapted (not included).
- Set up the connections (not supplied) 1''1 / 2 32-38 mm (Ref 200237 EAN13 : 3359192002376),
using PTFE tape.
- Install the suction and discharge of the pool by limiting the lengths and bends and avoiding traps.
It should not produce mechanical stress on the pump. For more comfort we suggest you install the
valves 1 / 4 turn (Ref : 200406 EAN13 : 335 919 200 4066) on the suction and discharge.
5
I GENERAL
100517
100518
106454
106455
106456
10.0
11.0
12.0
13.0
14.0
15.0
16.0
17.0
18.0
19.0
20.0
III INSTALLATION OF THE PIPE
- Check that the fan cover is well positioned and does not touch the propeller.
- Rotate the motor shaft by the fan screws with a screwdriver (the first start and after the rainy
season).
- Open the valves of the hydraulic system (if present) to fill to complete the pre-filter the water
pump. If necessary, remove the lid of the pre-filter and fill with water. Close it by checking the
correct position of the joint.
- Plug the pump into the mains. The pump begins in less than a minute.
- Damage resulting from dry running the pump are not guaranteed.
IV SERVICING
- Check that the fan cover is well positioned and does not touch the propeller.
- Rotate the motor shaft by the fan screws with a screwdriver (the first start and after the rainy
season).
- Open the valves of the hydraulic system (if present) to fill to complete the pre-filter the water
pump. If necessary, remove the lid of the pre-filter and fill with water. Close it by checking the
correct position of the joint.
- Plug the pump into the mains. The pump begins in less than a minute.
- Damage resulting from dry running the pump are not guaranteed.
A
ctions
Check the clogging of the prefilter
Clean the prefilter
Check the cover gasket
Drain and put in dry
Replace the water level
V MAINTENANCE
C
auses
x
x
x
air entry
x
x
Body of the pump without water
Hydraulic blocked
x
Dirty turbine
x
Improper attachment of the pump
x
Foreign body in the prefilter.
x
No voltage
x
Axis blocked
In other cases, consult your dealer
d
Aily
Daily
If dirty
Same cleaning prefilter
A wintering pool
If less than 2 / 3 of the height of the skimmer after
the bathing. (heat waves, prolonged absence, etc.)
s
olutions
Check the tightness of connections, hose
and seal lid
Fill the water pump housing
Clean the skimmer basket, pump prefilter,
then do a wash against the sand filter.
Requires the dismantling
Secure properly ground pump
Foreign body in the prefilter.
Reset circuit protection.
See 3.mise on (cover / Driver)