Wilo RAIN3 Série Notice De Montage Et De Mise En Service page 34

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

en
Menu no.
Parameter /
info
MP running
4.13
time
CP running
4.14
time
Total cycles
4.17
of panel
MP switch
4.18
cycles
CP switch
4.19
cycles
Switchgear
4.22
serial num-
ber
Software
4.24
version
Menu no.
Parameter /
info
Installation
5.00
Pump type
5.04
Number of
5.05
CP
Sensor
5.11
range pres-
sure
Sensor
5.21
range level
cistern
Level sensor
5.22
installation
height
High water
5.24
on threshold
cistern
Cistern
5.26
shape
Cistern high/
diameter
5.29
Pump kick
5.40
Pump kick
5.42
interval
PUmp kick
5.43
duration
34
Description
Min.
Max. Text
0
6553
5
0
6553
5
0
6553
5
0
6553
5
0
6553
5
0
9999
9999
9
0
9999
Parameters such as the rainwater storage tank dimensions have to be set in this
menu
Min.
Max. Text
HiMulti3-24; HiM-
ulti3-25; HiM-
ulti3-45
0
1
0.0
16.0
0.0
25.0
1
1000
1
1000
none; rectangle -
cylindric; cylindric
horizontal - sphere
1
1000
1
336
1
60
Default
Unit
Ac-
cess
level
0
h:mi
1
n
0
h:mi
1
n
0
1
0
1
0
1
0
1
V5.000
1
Default
Unit
Ac-
cess
level
1
HiMulti3-24
3
0
2
10.0
bar
3
5.00
m
3
15
cm
3
<5.51>+5
cm
3
rectangle
2
110
cm
3
On
2
24
h
2
5
s
2
Description
Operating time of MP
Operating time of CP
The number of power-on cycles for the
panel
The number of power-on cycles for MP
The number of power-on cycles for CP
ID of the panel
The software version of the installed ap-
plication
Description
The settings regarding the installation of
the panel in a system
Select of pump type to define pump
curves to get optimized set pressure for
switch-off refer in menu 1.05
Contains the number of pumps dedicated
to a cistern
Defines the range of the installed analog
pressure sensor
Defines the range of the installed analog
pressure sensor
Distance between ground level and in-
stalled height of sensor
The level threshold in cistern above high
water is reported (distance refer to 5.51)
5.22 < 5.51 < 5.24 < 5.29
If cistern has a defined shape it can be
selected here and can be used to calcu-
late volume capacity of the water
If a shape cylindric horizontal or sphere
for cistern is selected that is required a
diameter it is defined here for calculate
volume capacity 5.22 < 5.51 < 5.24 <
5.29
Enable or disable pump kick functionality
The interval between pump kicks or after
pumps have stopped until the next pump
kick
The time which pump is running during
pump kick
WILO SE 2019-10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rain 3-25 em

Table des Matières