WARNING
Read all safety warnings, instructions, illustrations
and specifications provided with this product.
Failure to follow all instructions listed below may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
Safety notes
Operating voltage 230 VAC!
Risk of injury from electric shock
Do not reverse L+N! Connect PE!
- Connection must be carried out by a certified
electrical technician
- Danger of crushing hands and fingers!
- Keep people away from the operating area of the drive
- Keep children away from the control
- Observe pressure load diagram of the rack and
pinion drive rack
- Use only in dry rooms
- Suitable for indoor mounting only.
Use rain detector in locations if there is a risk of rain
- Use option "-W" if mounted outdoors!
- Use unmodified original D+H parts only
- Observe the bracket-set mounting instructions
Observe enclosed red safety note!
Pressure load diagram
Maximum pressure load of the toothed rack is not
automatically identical with the maximum pressure
force of the drive!
1400
1200
1000
800
600
400
200
0
4/12
ZA 105-K
Stroke (mm)
Intended use
- Rack and pinion drive for electric opening and
closing of windows and flaps in the facade and
roof area
- Operating voltage 230 VAC
- Usable for smoke extraction, D+H Euro-SHEV in
accordance with DIN EN 12101-2 as well as daily
ventilation
- Suitable for indoor mounting only
Mounting information
- Swivel radius of the drive must have clearance
across the entire range of the stroke, otherwise
the rack and pinion drive and the suspension can
be damaged
- Drives with a stroke of ≥800 mm must not be
mounted „hung up at the bottom" (e.g. bracket UK)
- Eyebolt has to be adjusted so, that the drive is
disconnected with closed flap through it's inside
stop position damping. Brackets can be damaged
by to rigid adjustment!
- Technical clarification is required with D+H in case
of only tensile force applications of more than 500 N
Scope of supply
Drive unit with 2.5 m silicone cable. Depending on
the type of window, different bracket sets are
available separately.
Technical data
Type
Rated voltage
Performance
Nominal force
Runtime /100 mm
Nominal locking force
Service life
Duty cycle
Housing
Protective system
Temp.range
Emission sound
pressure level
Nominal stroke length
* + approx. 20 % cut-off reserve (temporary)
English
ZA 105-K
230 V AC, +10%/-15%
50 Hz
27 W / 30 VA
1000 N*
10 sec.
1100 N
>20 000 double strokes
30 % S2 (EN 60034-1)
no continuous voltage
Aluminium, PC
IP 65 ("-W" = IP 54)
-5 ... +75 °C
LpA ≤ 70 dB(A)
See type plate
99.823.58 2.6/02/16