Problem
The
touch
screen
display
shows
the
message
"EEPROM ERROR"
The
touch
screen
display
shows the message "NAND
ERROR"
The
touch
screen
display
shows the message "BOARD
OVERTEMPERATURE"
The
touch
screen
display
shows
the
message
"OVERCURRENT ERROR"
The
touch
screen
display
shows
the
message
"PRODUCT DENSITY HIGH"
The
touch
screen
display
shows
the
message
"MACHINE CODE ERROR"
Data di emissione: Dicembre, 2013
72/124
Possible cause
•
The main board memory is not working
•
The main board images memory is not
working
•
The main board temperature is too high
•
The current absorption is too high
•
The product consistency is too high and
the motor is not able to rotate
•
The unit software has not been set
properly
•
•
•
•
•
•
Revisione: 5
Solution
Replace the main board
Replace the main board
Check the root cause and solve
The product density or/and the
auger rotation speed are too
high,
modify
the
functioning
parameters
Switch the unit off, wait for the
product
temperature
decrease
and before operate again modify
the
product
temperature
increasing it.
Replace the main board
Pag. :