Télécharger Imprimer la page

S+S Regeltechnik THERMASGARD TF 54 Série Notice D'instruction

Masquer les pouces Voir aussi pour THERMASGARD TF 54 Série:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

D G F r
6000-3050-0000-2XX 30500-2021 V211 02 ⁄ 2021
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Tauch- ⁄ Einschraub- ⁄ Kanal-Temperaturfühler,
mit passivem Ausgang
G
Operating Instructions, Mounting & Installation
Immersion ⁄ screw-in ⁄ duct temperature sensor
with passive output
F
Notice d'instruction
Sonde de température à immerger ⁄ à visser ⁄ en gaine,
avec sortie passive
r
Руководство по монтажу и обслуживанию
Погружной ⁄ ввинчиваемый ⁄ канальный датчик температуры,
с пассивным выходом
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
TF 54 xx
S+S REGELTECHNIK GMBH
THURN-UND-TAXIS - STR. 22
90411 NÜRNBERG ⁄ GERMANY
FON +49 ( 0 ) 911 ⁄ 5 19 47- 0
mail@SplusS.de
www.SplusS.de
TF 54
(IP 54)
TF 54 - KV
(IP 65)
TF 54 - Q
(IP 65)
CARTONS
ET EMBALLAGE
PAPIER À TRIER

Publicité

loading

Sommaire des Matières pour S+S Regeltechnik THERMASGARD TF 54 Série

  • Page 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH THURN-UND-TAXIS - STR. 22 90411 NÜRNBERG ⁄ GERMANY CARTONS FON +49 ( 0 ) 911 ⁄...
  • Page 2 D G F r TF 54 xx THERMASGARD ®  ø70 ~ 80 M20 x1.5 2-Leiteranschluss (Standard) TF 54 xx Maßzeichnung 2-wire connection (Standard) Dimensional drawing ø70 ~ 80 1x 2 fils (Standard) Plan coté Двухпроводное соединение M20 x1.5 Габаритный чертеж (стандартное...
  • Page 3 THERMASGARD ® TF 54 Rev. 2021 - V17 Widerstandsthermometer ⁄ Temperaturfühler THERMASGARD ® TF 54 mit passivem Ausgang, mit 1x Zweileiterschaltung Anschlusskopf aus Aluminium (optional mit Kabelverschraubung oder M12-Steckverbinder nach DIN (Standard) EN 61076-2-101) und geradem Schutzrohr. Ein Grundgerät in vier Varianten durch Kombination mit Zubehör, z.B.
  • Page 4 Allgemeine Informationen Messprinzip für HLK - (HVAC) -Temperaturfühler allgemein: Das Messprinzip der Temperaturfühler beruht darauf, dass der innen liegende Sensor ein temperaturabhängiges Widerstandssignal abgibt. Die Art des innen liegenden Sensors bestimmt das Ausgangssignal. Man unterscheidet die nachfolgenden passiven ⁄ aktiven Temperatursensoren: a) Pt 100 - Messwiderstand (nach DIN EN 60 751) b) Pt 1000 - Messwiderstand (nach DIN EN 60751) c) Ni 1000 - Messwiderstand (nach DIN EN 43 760, TCR=6180 ppm ⁄...
  • Page 5 Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Anschluss Der Einbau hat unter Beachtung der Übereinstimmung der vorliegenden technischen Parameter der Thermometer mit den realen Einsatzbe- der Geräte darf nur an Sicherheitskleinspannung er folgen. Folgeschäden, dingungen zu erfolgen, insbesondere: welche durch Fehler an diesem Gerät entstehen, sind von der Gewährlei- –...
  • Page 6 THERMASGARD ® TF 54 Rev. 2021 - V17 Resistance thermometer ⁄ temperature sensor THERMASGARD ® TF 54 with passive output, with 1x two-wire connection connecting head made from aluminium (optionally with cable gland or M12 connector according to (standard) DIN EN 61076-2-101) and straight protective tube. A basic unit in four variants through combina- tion with accessories, eg, for robust applications with a separate immersion sleeve made from stainless steel.
  • Page 7 General notes Measuring principle of HVAC temperature sensors in general: The measuring principle of temperature sensors is based on an internal sensor that outputs a temperature-dependent resistance signal. The type of the internal sensor determines the output signal. The following active ⁄ passive temperature sensors are distinguished: a) Pt 100 measuring resistor (according to DIN EN 60 751) b) Pt 1000 measuring resistor (according to DIN EN 60751) c) Ni 1000 measuring resistor (according to DIN EN 43 760, TCR = 6180 ppm ⁄...
  • Page 8 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices must Before mounting, make sure that the existing thermometer‘s technical parameters comply with the actual conditions at the place of utilization, in only be connected to safety extra-low voltage. Consequential damages particular in respect of: caused by a fault in this device are excluded from warranty or liability.
  • Page 9 THERMASGARD ® TF 54 Rev. 2021 - V17 Thermomètre à résistance / sonde de température THERMASGARD ® TF 54 avec sortie passive, 1x 2 fils tête de raccordement en aluminium (en option presse-étoupe ou connecteur M12 selon DIN (Standard) EN 61076-2-101) et tube de protection droite. Un appareil de base en quatre variantes en combi- naison avec des accessoires, par ex.
  • Page 10 Généralités Principe de mesure des sondes de température pour applications CVC (HVAC) en général: Le principe de mesure se base sur le fait que le capteur à l’intérieur génère un signal de résistance dépendant de la température. Le signal de sortie est déterminé...
  • Page 11 Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Effectuer l’installation en respectant la conformité des paramètres techniques correspondants des thermomètres aux conditions d’utilisation Veillez à ne brancher l’appareil que sur un réseau de très basse tension de réelles, notamment : sécurité.
  • Page 12 THERMASGARD ® TF 54 Rev. 2021 - V17 Термометр сопротивления / датчик температуры THERMASGARD ® TF 54 с пассивным выходом, 1 Двухпроводное подключение с присоединительной головкой из алюминия (опционально с резьбовым кабельным вводом или (стандартное исполнение) разъемом M12 согласно DIN  EN 61076-2-101) и прямой защитной трубкой. Базовый прибор в четырех...
  • Page 13 Указания к продуктам Общий принцип измерения для датчика температуры HLK (HVAC): Принцип измерения температуры основан на зависимости электрического сопротивления чувствительного элемента (сенсора), находящегося внутри датчика, от температуры. Выходной сигнал сопротивления определяется типом чувствительного элемента. Различают следующие пассивные ⁄ активные чувствительные элементы: а) измерительный...
  • Page 14 Монтаж и ввод в эксплуатацию Приборы следует устанавливать в обесточенном состоянии. Подключение Монтаж следует осуществлять с учетом соответствия прилагаемых технических параметров термометра реальным условиям эксплуатации, должно осуществляться исключительно к безопасно малому напряжению. в особенности: Повреждения приборов вследствие несоблюдения упомянутых требований –...
  • Page 15 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r Widerstandskennlinien für passive Temperatursensoren Resistance characteristics of passive temperature sensors Courbes caractéristiques pour capteurs de température passive Характеристики сопротивления пассивных датчиков температуры Pt 100 Pt 1000 Ni 1000 Ni 1000 LM235Z TK 5000 (KP10) 1.8 kOhm 10 kOhm 20 kOhm °...

Ce manuel est également adapté pour:

Thermasgard tf 54-kvThermasgard tf 54-q