Ducati CTR34 Manuel D'emploi page 27

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connector J5
FS3 Faston – Backup battery's positive pole connection
FS4 Faston – Backup battery's negative pole connection
Connector J2
FS1 Faston – Power supply from the electric transformer
FS2 Faston – Power supply from the electric transformer
Connection of the devices
Motor 1 – Terminals 7 and 8 on J4
Motor 2 – Terminals 5 and 6 on J4
Blinker – Terminals 3 and 4 on J4
Electric lock – Terminals 9 e 10 on J4
Photo-cells power supply – Terminals 1 and 2 on J4
NC photo-cell contact – Terminals 6 and 4 on J1
NC stop push-button – Terminals 5 and 4 on J1
NC photostop contact – Terminals 7 and 8 on J1
NO start push-button – Terminals 1 and 3 on J1
NO pedestrian start push-button – Terminals 1 and 2 on J1
Aerial – Terminals 1 and 2 on J3
Important: Before starting the gate check the following conditions :
a) connections to the electronic card
b) electric contacts' switching
c) state of the protection fuses
d) leds' correct operation.
27
ENGLISH

Publicité

Chapitres

Table des Matières
loading

Table des Matières