Connection With The Mains; Cleaning And Maintenance - EuroLite LED DWL-2 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Procedure:
The luminaire should be installed outside areas where persons may walk by or be seated.
Caution: Luminaires may cause severe injuries when crashing down! If you have doubts concerning the
safety of a possible installation, do NOT install the luminaire!
Always install the device via all fixation holes.
Do only use appropriate screws and make sure that the screws are properly connected with the ground.
Before taking into operation for the first time, the installation has to be approved by an expert!

Connection with the mains

The electric connection must only be carried out by a qualified electrician!
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
DANGER TO LIFE!
DANGER TO LIFE!
International
L
N
10/19
00029828.DOC, Version 1.1

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Led dwl-4Led dwl-6

Table des Matières